MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2024.06.011

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2024

Haemodynamic and clinical outcomes at 5 years according to predicted prosthesis-patient mismatch after transcatheter aortic valve replacement.

Sugiyama Yoichi, Miyashita Hirokazu, Ochiai Tomoki, Shishido Koki, Jalanko Mikko, Yamanaka Futoshi, Vähäsilta Tommi, Saito Shigeru, Laine Mika, Moriyama Noriaki

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/PURPOSE: Although the impact of predicted prosthesis-patient mismatch (PPMP) on outcomes after surgical aortic valve replacement is well established, studies on PPMP in transcatheter aortic valve replacement (TAVR) are limited. This study investigated the effects of PPMp on haemodynamic and 5-year clinical outcomes after TAVR.

METHODS/MATERIALS: We analysed 1733 patients who underwent TAVR. PPMp was defined using two different methods: 1) normal reference values of the effective orifice area for each valve type and size indexed to body surface area (PPMp1; n = 1733) and 2) reference values for aortic annulus area or perimeter assessed with pre-procedural computed tomography indexed to body surface area (PPMp2; n = 1227). The primary endpoint was the composite of all-cause death and/or rehospitalisation for heart failure at 5 years.

RESULTS

The incidence of PPMp1 was 11.7 % and 0.8 % in moderate and severe cases, respectively. PPMp2 was classified as either moderate (3.8 %) or severe (0 %). Rates of residual mean aortic gradient ≥20 mmHg significantly increased depending on PPMp1 severity (no PPMp1: 3.1 % vs. moderate PPMp1: 26.8 % vs. severe PPMp1: 53.9 %, p < 0.0001) and PPMp2 (no PPMp2: 4.1 % vs. moderate PPMp2: 12.8 %, p = 0.0049). Neither of PPMP methods were associated with the composite outcome in total cohort; however, PPMP1 was significantly related to worse clinical outcomes at 5 years among patients with reduced left ventricular ejection fraction (LVEF) in multivariate analysis (HR: 1.87; 95 % CI: 1.02-3.43).

CONCLUSIONS

The impact of PPMP on TAVR clinical outcomes may not be negligible in patients with low LVEF.

Для цитирования: Sugiyama Yoichi, Miyashita Hirokazu, Ochiai Tomoki, Shishido Koki, Jalanko Mikko, Yamanaka Futoshi, Vähäsilta Tommi, Saito Shigeru, Laine Mika, Moriyama Noriaki. Haemodynamic and clinical outcomes at 5 years according to predicted prosthesis-patient mismatch after transcatheter aortic valve replacement.. Cardiovascular revascularization medicine : including molecular interventions. 2024. DOI: 10.1016/j.carrev.2024.06.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.