Медицинская библиотека · Clinical hemorheology and microcirculation · 2024

Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation.

Stern Manuel, Baasen Sven, Wischmann Patricia, Herbrand Theresa, Schremmer Johanna, Maier Oliver, Stern Marc, Jung Christian, Heiss Christian, Kelm Malte, Sansone Roberto, Busch Lucas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on the effect of transcatheter aortic valve implantation (TAVI) on peripheral microcirculation are limited.

OBJECTIVE

The aim of this study is to evaluate peripheral microvascular tissue saturation (StO2) before and after TAVI in relation to central and peripheral hemodynamics, cardiac and renal function.

METHODS

In this single-center prospective study, patients with severe aortic stenosis (sAS) scheduled for TAVI or cardiac catheterization (control) were assessed before and up to five days after the procedure. Cardiac function including cardiac output (CO) was assessed by echocardiography. Brachial (bBP) and central blood pressure (cBP), ankle brachial index (ABI), and parameters of arterial stiffness, including augmentation pressure (AP) and augmentation index adjusted for heart rate (AIx@HR75) were measured to assess hemodynamic changes. StO2 was measured in all extremities using a near-infrared spectroscopy (NIRS) camera. Renal function was measured by creatinine levels.

RESULTS

26 patients underwent TAVI and 11 patients served as control. Cardiac output was significantly increased, whereas hemodynamic parameters and peripheral StO2 were significantly decreased after TAVI. At follow-up, StO2 returned to baseline values. Changes in StO2 were negatively related to creatinine levels.

CONCLUSION

Transcatheter aortic valve implantation causes a temporary decrease in microvascular tissue saturation that is associated with renal function.

Для цитирования: Stern Manuel, Baasen Sven, Wischmann Patricia, Herbrand Theresa, Schremmer Johanna, Maier Oliver, Stern Marc, Jung Christian, Heiss Christian, Kelm Malte, Sansone Roberto, Busch Lucas. Temporary decrease in microvascular tissue saturation after transcatheter aortic valve implantation.. Clinical hemorheology and microcirculation. 2024. DOI: 10.3233/ch-232051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.