MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.shj.2024.100282

Медицинская библиотека · Structural heart : the journal of the Heart Team · 2024

Invasive Assessment of Right Ventricular to Pulmonary Artery Coupling Improves 1-year Mortality Prediction After Transcatheter Aortic Valve Replacement and Anticipates the Persistence of Extra-Aortic Valve Cardiac Damage.

Lachmann Mark, Hesse Amelie, Trenkwalder Teresa, Xhepa Erion, Rheude Tobias, von Scheidt Moritz, Covarrubias Héctor Alfonso Alvarez, Rippen Elena, Hramiak Oksana, Pellegrini Costanza, Schuster Tibor, Yuasa Shinsuke, Schunkert Heribert, Kastrati Adnan, Kupatt Christian, Laugwitz Karl-Ludwig, Joner Michael

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The interplay between the right ventricle and the pulmonary artery, known as right ventricular to pulmonary artery (RV-PA) coupling, is crucial for assessing right ventricular systolic function against the afterload from the pulmonary circulation. Pulmonary artery pressure levels are ideally measured by right heart catheterization. Yet, echocardiography represents the most utilized method for evaluating pulmonary artery pressure levels, albeit with limitations in accuracy. This study therefore aims to evaluate the prognostic significance of right ventricular to pulmonary artery (RV-PA) coupling expressed as tricuspid annular plane systolic excursion (TAPSE) related to systolic pulmonary artery pressure (sPAP) levels measured by right heart catheterization (TAPSE/sPAPinvasive) or estimated by transthoracic echocardiography (TAPSE/sPAPechocardiography) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR).

METHODS

Using data from a bicentric registry, this study compares TAPSE/sPAPinvasive vs. TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR.

RESULTS

Among 333 patients with complete echocardiography and right heart catheterization data obtained before TAVR, their mean age was 79.8 ± 6.74 years, 39.6% were female, and general 1-year survival was 89.8%. sPAPinvasive and sPAPechocardiography showed only moderate correlation (Pearson correlation coefficient R: 0.53, p value: <0.0001). TAPSE/sPAPinvasive was superior to TAPSE/sPAPechocardiography in predicting 1-year all-cause mortality after TAVR (area under the curve: 0.662 vs. 0.569, p value: 0.025). Patients with reduced TAPSE/sPAPinvasive levels (< 0.365 mm/mmHg) evidenced significantly lower 1-year survival rates than patients with preserved TAPSE/sPAPinvasive levels (81.8 vs. 93.6%, p value: 0.001; hazard ratio for 1-year mortality: 3.09 [95% confidence interval: 1.55-6.17]). Echocardiographic follow-up data revealed that patients with reduced RV-PA coupling suffer from persistent right ventricular dysfunction (TAPSE: 16.6 ± 4.05 mm vs. 21.6 ± 4.81 mm in patients with preserved RV-PA coupling) and severe tricuspid regurgitation (diagnosed in 19.7 vs. 6.58% in patients with preserved RV-PA coupling).

CONCLUSIONS

RV-PA coupling expressed as TAPSE/sPAPinvasive can refine stratification of severe aortic stenosis patients into low-risk and high-risk cohorts for mortality after TAVR. Moreover, it can help to anticipate persistent extra-aortic valve cardiac damage, which will demand further treatment.

Для цитирования: Lachmann Mark, Hesse Amelie, Trenkwalder Teresa, Xhepa Erion, Rheude Tobias, von Scheidt Moritz, Covarrubias Héctor Alfonso Alvarez, Rippen Elena, Hramiak Oksana, Pellegrini Costanza, Schuster Tibor, Yuasa Shinsuke, Schunkert Heribert, Kastrati Adnan, Kupatt Christian, Laugwitz Karl-Ludwig, Joner Michael. Invasive Assessment of Right Ventricular to Pulmonary Artery Coupling Improves 1-year Mortality Prediction After Transcatheter Aortic Valve Replacement and Anticipates the Persistence of Extra-Aortic Valve Cardiac Damage.. Structural heart : the journal of the Heart Team. 2024. DOI: 10.1016/j.shj.2024.100282.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.