MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-60692-5

Медицинская библиотека · Scientific reports · 2024

Real-world experience utilizing the nuvision 4D intracardiac echocardiography catheter for left atrial appendage closure.

Adams Alex, Mahmood Riaz, Balaji Nivedha, Dixit Priyadarshini, Chandra Shalabh, Weisman David

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.

Для цитирования: Adams Alex, Mahmood Riaz, Balaji Nivedha, Dixit Priyadarshini, Chandra Shalabh, Weisman David. Real-world experience utilizing the nuvision 4D intracardiac echocardiography catheter for left atrial appendage closure.. Scientific reports. 2024. DOI: 10.1038/s41598-024-60692-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.