MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2024.04.008

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2024

Transcarotid versus transfemoral transcatheter aortic valve replacement: A systematic review and meta-analysis.

Munguti Cyrus, Ndunda Paul M, Abukar Abdullah, Jawad Mohammed Abdel, Vindhyal Mohinder R, Fanari Zaher

Сравнительное исследованиеСтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

In the 2021 Transcatheter Valve Therapy (TVT) registry, 8.9 % of patients underwent TAVR via access sites other than the femoral artery. Transthoracic approaches may be contraindicated in some patients and may be associated with poorer outcomes. Therefore other alternative access routes are increasingly being performed. We conducted a systematic review of the literature on transcarotid transcatheter aortic valve replacement (TC-TAVR) and meta-analysis comparing outcomes of TC-TAVR and other access routes.

METHODS

We comprehensively searched for controlled randomized and non-randomized studies from 4 online databases. We presented data using risk ratios (95 % confidence intervals) and measured heterogeneity using Higgins' I2.

RESULTS

Sixteen observational studies on transcarotid TAVR were included in the analysis; 4 studies compared TC-TAVR vs TF-TAVR. The mean age and STS score for patients undergoing TC-TAVR were 80 years and 7.6 respectively. For TF-TAVR patients, mean age and STS score were 81.2 years and 6.5 respectively. There was no difference between patients undergoing TC-TAVR and TF-TAVR in the following 30-day outcomes: MACE [8.4 % vs 6.7 %; OR 1.32 (95 % CI 0.71-2.46 p = 0.38) I2 = 0 %], mortality [5.6 % vs 4.0 %; OR 0.42 (95 % CI 0.60-3.37, P = 0.42) I2 = 0 %] and stroke [0.7 % vs 2.3 %; OR 0.49 (95 % CI 0.09-2.56, P = 0.40) I2 = 0 %]. There was no difference in 30-day major vascular complications [0.7 % vs 3 %; OR 0.55 (95 % CI 0.06-5.29, P = 0.61) I2 = 39 %], major bleeding [0.7 % vs 3.8 %; OR 0.39 (95 % CI 0.09-1.67, P = 0.21) I2 = 0 %], and moderate or severe aortic valve regurgitation [8.6 % vs 9.9 %; OR 0.89 (95 % CI 0.48-1.65, P = 0.72) I2 = 0 %].

CONCLUSION

There are no significant differences in mortality, stroke MACE and major or life-threatening bleeding or vascular complications when TC-TAVR is compared to TF-TAVR approaches.

Для цитирования: Munguti Cyrus, Ndunda Paul M, Abukar Abdullah, Jawad Mohammed Abdel, Vindhyal Mohinder R, Fanari Zaher. Transcarotid versus transfemoral transcatheter aortic valve replacement: A systematic review and meta-analysis.. Cardiovascular revascularization medicine : including molecular interventions. 2024. DOI: 10.1016/j.carrev.2024.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.