Safety and Efficacy of Mini-Invasive Left Atrial Appendage Closure: A Propensity-Score Analysis.

Denis Catherine, Clerfond Guillaume, Chalard Aurélie, Riocreux Clément, Pereira Bruno, Lamallem Ouarda, Guizani Taieb, Catalan Pierre-Antoine, Boudias Antoine, Jean Frédéric, Bouchant-Pioche Marion, Abu-Alrub Saer, Combaret Nicolas, Souteyrand Géraud, Motreff Pascal, Jabaudon Matthieu, Futier Emmanuel, Massoullie Grégoire, Eschalier Romain

СтатьяПоддержка исследования: вне правительства СШАКомментарийПеревод пока не подготовлен

Аннотация

BACKGROUND

Left atrial appendage closure (LAAC) for prevention of stroke is validated in patients with nonvalvular atrial fibrillation (NVAF) contraindicated to oral anticoagulation. General anaesthesia (GA) is often used for procedural guidance by transesophageal echocardiography (TEE); however, its use may be challenging in some patients. The aim of the study was to evaluate the safety and the midterm efficacy of a mini-invasive LAAC strategy using micro-TEE under procedural sedation.

METHODS

Comparison by propensity score of 2 cohorts of consecutive patients who underwent LAAC: standard TEE-guided LAAC (3-dimensional [3D] TEE under GA) and mini-invasive LAAC strategy (micro-TEE under procedural sedation). The primary endpoint was a composite of embolic or bleeding events, significant per procedural complication, and cardiovascular deaths within 3 months after LAAC.

RESULTS

In total, 432 patients were included (78.7 ± 8 years old, 32.4% of women, CHA2DS2VASC score: 4.9 ± 1.1); 127 patients underwent mini-invasive LAAC strategy and were compared with 305 patients standard TEE-guided LAAC. The mini-invasive strategy was achieved in 122 of 127 (96.1%) planned patients. The primary endpoint occurred in 11.2% of patients from the mini-invasive LAAC strategy group and in 10.3% of patients from the standard TEE group (absolute difference = 0.9% [-6.4; 4.5], hazard ratio = 1.11 [0.56; 2.19], P = 0.76). Procedural times, fluoroscopy duration, and hospital stays were shorter in the mini-invasive LAAC strategy group (P < 0.001).

CONCLUSIONS

The mini-invasive LAAC strategy is safe and effective compared with the standard TEE-guided LAAC strategy. A mini-invasive LAAC strategy may also be an important tool to help physicians to treat more patients as LAAC indications evolve in the future.

Для цитирования: Denis Catherine, Clerfond Guillaume, Chalard Aurélie, Riocreux Clément, Pereira Bruno, Lamallem Ouarda, Guizani Taieb, Catalan Pierre-Antoine, Boudias Antoine, Jean Frédéric, Bouchant-Pioche Marion, Abu-Alrub Saer, Combaret Nicolas, Souteyrand Géraud, Motreff Pascal, Jabaudon Matthieu, Futier Emmanuel, Massoullie Grégoire, Eschalier Romain. Safety and Efficacy of Mini-Invasive Left Atrial Appendage Closure: A Propensity-Score Analysis.. The Canadian journal of cardiology. 2024. DOI: 10.1016/j.cjca.2024.03.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.