BACKGROUND

The Cox maze (CM) procedure is routinely performed using surgical ablation technology. Reports are scarce on long-term outcomes of CM, especially for a large series of patients. This study examined the potential impact of surgical ablation energy source on safety and long-term efficacy of concomitant CM procedures.

METHODS

The study sample consisted of 709 concomitant CM-treated patients operated on with cryothermal energy only (group 1; n = 386) or combination of cryothermal and bipolar radiofrequency (group 2; n = 323). Data were collected prospectively on perioperative outcomes, rhythm status, survival, and clinical events. Propensity score matching conducted by energy source resulted in 298 patients per group.

RESULTS

Perioperative outcomes included stroke (n = 4), reoperation for bleeding (n = 23), renal failure requiring temporary dialysis (n = 18), readmissions before 30 days (n = 86), and operative death before 30 days (n = 16; ratio of observed to expected mortality [O/E ratio], 0.50). Independent predictors for 1-year and 5-year rhythm success were a shorter history of atrial fibrillation (1-year odds ratio [OR], 0.93, p = 0.001; 5-year OR, 0.93, p = 0.042) and cryothermia alone (1-year OR=1.77, p = 0.020; 5-year OR = 2.29, p = 0.009). After matching, group 1 had significantly higher sinus rhythm without antiarrhythmic drugs at 6 months (79% vs 70%; p = 0.016), 36 months (81% vs 69%; p = 0.010), and 60 months (75% vs 57%; p = 0.008). Stroke incidence was lower for group 1 (0.7% vs 3%; p = 0.033), with no difference in major bleeding (10% vs 11%; p = 0.597). Groups had similar survival rates (log rank, 0.6; p = 0.452).

CONCLUSIONS

Concomitant CM procedures performed with cryothermal energy alone or combined with bipolar radiofrequency ablation are safe and exceedingly effective. The association of cryothermal energy alone with higher rates of sinus rhythm and stroke reduction should be investigated further.

Для цитирования: Ad Niv, Holmes Sari D, Rongione Anthony J, Massimiano Paul S, Fornaresio Lisa M. Does Surgical Ablation Energy Source Affect Long-Term Success of the Concomitant Cox Maze Procedure?. The Annals of thoracic surgery. 2017. DOI: 10.1016/j.athoracsur.2017.04.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.