MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-024-02360-2

Медицинская библиотека · Heart and vessels · 2024

Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and "Virtual TEE" reconstructed from computed tomography for pre-procedural planning of device closure.

Cho Natsuki, Nakajima Yoshifumi, Kubo Shunsuke, Hara Hidehiko, Nanasato Mamoru, Hozawa Maiko, Doi Akio, Morino Yoshihiro

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.

Для цитирования: Cho Natsuki, Nakajima Yoshifumi, Kubo Shunsuke, Hara Hidehiko, Nanasato Mamoru, Hozawa Maiko, Doi Akio, Morino Yoshihiro. Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and "Virtual TEE" reconstructed from computed tomography for pre-procedural planning of device closure.. Heart and vessels. 2024. DOI: 10.1007/s00380-024-02360-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.