Venoarterial extracorporeal membrane oxygenation for cardiopulmonary resuscitation: A retrospective study comparing the outcomes of fluoroscopy.

Tanaka Soichi, Tachibana Shunsuke, Toyohara Takashi, Sonoda Hajime, Yamakage Michiaki

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Extracorporeal cardiopulmonary resuscitation (ECPR) using venoarterial extracorporeal membrane oxygenation is performed for out-of-hospital cardiac arrest; however, it is associated with a risk of several complications.

OBJECTIVE

To investigate whether the fluoroscopy equipment was removed from the emergency department (ED) and whether it would be beneficial to transport the patient to the fluoroscopy room to reduce vascular complications without affecting the induction time.

METHODS

This single-center, retrospective, before-and-after analysis was conducted at a tertiary emergency medical center and included 59 patients who underwent ECPR for out-of-hospital cardiac arrest between May 2017 and March 2022. The patients were divided into two groups: those who underwent cannulation in the ED without fluoroscopy (ED-ECPR group) and those who were transferred directly from the ED to the cardiac angiography room (ECPR call group).

RESULTS

The rate of vascular complications associated with ECPR was significantly lower in the ECPR group than in the ED-ECPR group (40.6 % [14/32] vs. 10 % [2/20], respectively; p = 0.014). The duration from ED arrival to venoarterial extracorporeal membrane oxygenation initiation was similar in the two groups (median: 23.0 min in the ED-ECPR group vs. 25.5 min in the ECPR call group, p = 0.71). Results adjusted for confounding factors showed that performing ECPR under fluoroscopy was a consistent and independent element of vascular complication rates (adjusted odds ratio: 9.92, 95 % confidence interval: 2.04 to 81.2, p = 0.011).

CONCLUSIONS

Fluoroscopy-guided ECPR can significantly reduce the incidence of vascular complications even if the ED and fluoroscopy room are far apart. However, no significant difference was observed in the time required to establish ECPR in the cardiac catheterization laboratories.

Для цитирования: Tanaka Soichi, Tachibana Shunsuke, Toyohara Takashi, Sonoda Hajime, Yamakage Michiaki. Venoarterial extracorporeal membrane oxygenation for cardiopulmonary resuscitation: A retrospective study comparing the outcomes of fluoroscopy.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e24565.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.