MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehad828

Медицинская библиотека · European heart journal · 2024

Residual leaks following percutaneous left atrial appendage occlusion and outcomes: a meta-analysis.

Samaras Athanasios, Papazoglou Andreas S, Balomenakis Charalampos, Bekiaridou Alexandra, Moysidis Dimitrios V, Patsiou Vasiliki, Orfanidis Antonios, Giannakoulas George, Kassimis George, Fragakis Nikolaos, Saw Jacqueline, Landmesser Ulf, Alkhouli Mohamad Adnan, Tzikas Apostolos

МетаанализСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIMS: Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion.

METHODS

A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks.

RESULTS

Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52-2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08-1.24), and major bleeding (pOR 1.12, 95% CI: 1.03-1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35-2.47), 2.13 (95% CI: 1.04-4.35), 4.14 (95% CI: 2.07-8.27), and 4.44 (95% CI: 2.09-9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84-2.50 and 0.52-2.07, respectively).

CONCLUSIONS

Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.

Для цитирования: Samaras Athanasios, Papazoglou Andreas S, Balomenakis Charalampos, Bekiaridou Alexandra, Moysidis Dimitrios V, Patsiou Vasiliki, Orfanidis Antonios, Giannakoulas George, Kassimis George, Fragakis Nikolaos, Saw Jacqueline, Landmesser Ulf, Alkhouli Mohamad Adnan, Tzikas Apostolos. Residual leaks following percutaneous left atrial appendage occlusion and outcomes: a meta-analysis.. European heart journal. 2024. DOI: 10.1093/eurheartj/ehad828.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.