MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2023.131641

Медицинская библиотека · International journal of cardiology · 2023

Comparing safety and efficacy: MemoLefort versus watchman for left atrial appendage closure.

Li Ling, Qian Sang, Fu Jia-Yang, Wang Zhe-Ning, Jiang Ting, Lin Yuan-Nan, Yao Tao, Liu Jing-Chen, Pan Yang-Qi, Li Yue-Chun

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The MemoLefort is a new plug occluder for left atrial appendage closure (LAAC) in patients with atrial fibrillation (AF). This study compares the safety and efficacy of MemoLefort and the well-established Watchman occluder for LAAC.

METHODS

Between January 2021 and September 2022, a cohort of 189 consecutive patients who underwent LAAC with MemoLefort or Watchman at The Second Affiliated Hospital of Wenzhou Medical University were included. Patients with MemoLefort or Watchman devices were compared in terms of the primary safety endpoints encompassing major periprocedural complications and major bleeding events at follow-up, the primary efficacy endpoint of all-cause stroke, systemic embolism and cardiovascular/unexplained death, and the combined hazard endpoint, a composite of all the above-mentioned hazards.

RESULTS

Of the MemoLefort group (n = 83) and Watchman group (n = 106), the mean age, CHA2DS2-VASc score, and HAS-BLED score were 67.6 ± 9.2 vs. 69.0 ± 10.6 years, 3.9 ± 1.9 vs. 3.8 ± 1.9, and 1.6 ± 1.0 vs. 1.7 ± 1.2, respectively. After a median follow-up duration of 198 (99-329) vs. 334 (171-497) days, the primary endpoints of efficacy [2/49, 4.1% (MemoLefort) vs. 2/97, 2.1% (Watchman); hazard ratio (HR), 1.50; 95% confidence interval (CI), 0.20-11.08; P = 0.68] and safety (1/49, 2.0% vs. 5/97, 5.2%; HR, 0.26; 95% CI, 0.05-1.31; P = 0.19), as well as the combined hazard endpoint (3/49, 61% vs. 6/97, 6.2%; HR, 0.70; 95% CI, 0.18-2.58; P = 0.59) were similar between groups.

CONCLUSIONS

In the short term, LAAC with MemoLefort provided similar efficacy, safety, and net clinical benefit in comparison to Watchman devices.

Для цитирования: Li Ling, Qian Sang, Fu Jia-Yang, Wang Zhe-Ning, Jiang Ting, Lin Yuan-Nan, Yao Tao, Liu Jing-Chen, Pan Yang-Qi, Li Yue-Chun. Comparing safety and efficacy: MemoLefort versus watchman for left atrial appendage closure.. International journal of cardiology. 2023. DOI: 10.1016/j.ijcard.2023.131641.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.