MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jead324

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2024

Artificial intelligence-enabled assessment of right ventricular to pulmonary artery coupling in patients undergoing transcatheter tricuspid valve intervention.

Fortmeier Vera, Lachmann Mark, Stolz Lukas, von Stein Jennifer, Unterhuber Matthias, Kassar Mohammad, Gerçek Muhammed, Schöber Anne R, Stocker Thomas J, Omran Hazem, Körber Maria I, Hesse Amelie, Harmsen Gerhard, Friedrichs Kai Peter, Yuasa Shinsuke, Rudolph Tanja K, Joner Michael, Pfister Roman, Baldus Stephan, Laugwitz Karl-Ludwig, Windecker Stephan, Praz Fabien, Lurz Philipp, Hausleiter Jörg, Rudolph Volker

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: Right ventricular to pulmonary artery (RV-PA) coupling has been established as a prognostic marker in patients with severe tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve interventions (TTVI). RV-PA coupling assesses right ventricular systolic function related to pulmonary artery pressure levels, which are ideally measured by right heart catheterization. This study aimed to improve the RV-PA coupling concept by relating tricuspid annular plane systolic excursion (TAPSE) to mean pulmonary artery pressure (mPAP) levels. Moreover, instead of right heart catheterization, this study sought to employ an extreme gradient boosting (XGB) algorithm to predict mPAP levels based on standard echocardiographic parameters.

METHODS AND

RESULTS

This multicentre study included 737 patients undergoing TTVI for severe TR; among them, 55 patients from one institution served for external validation. Complete echocardiography and right heart catheterization data were available from all patients. The XGB algorithm trained on 10 echocardiographic parameters could reliably predict mPAP levels as evaluated on right heart catheterization data from external validation (Pearson correlation coefficient R: 0.68; P value: 1.3 × 10-8). Moreover, predicted mPAP (mPAPpredicted) levels were superior to echocardiographic systolic pulmonary artery pressure (sPAPechocardiography) levels in predicting 2-year mortality after TTVI [area under the curve (AUC): 0.607 vs. 0.520; P value: 1.9 × 10-6]. Furthermore, TAPSE/mPAPpredicted was superior to TAPSE/sPAPechocardiography in predicting 2-year mortality after TTVI (AUC: 0.633 vs. 0.586; P value: 0.008). Finally, patients with preserved RV-PA coupling (defined as TAPSE/mPAPpredicted > 0.617 mm/mmHg) showed significantly higher 2-year survival rates after TTVI than patients with reduced RV-PA coupling (81.5% vs. 58.8%, P < 0.001). Moreover, independent association between TAPSE/mPAPpredicted levels and 2-year mortality after TTVI was confirmed by multivariate regression analysis (P value: 6.3 × 10-4).

CONCLUSION

Artificial intelligence-enabled RV-PA coupling assessment can refine risk stratification prior to TTVI without necessitating invasive right heart catheterization. A comparison with conservatively treated patients is mandatory to quantify the benefit of TTVI in accordance with RV-PA coupling.

Для цитирования: Fortmeier Vera, Lachmann Mark, Stolz Lukas, von Stein Jennifer, Unterhuber Matthias, Kassar Mohammad, Gerçek Muhammed, Schöber Anne R, Stocker Thomas J, Omran Hazem, Körber Maria I, Hesse Amelie, Harmsen Gerhard, Friedrichs Kai Peter, Yuasa Shinsuke, Rudolph Tanja K, Joner Michael, Pfister Roman, Baldus Stephan, Laugwitz Karl-Ludwig, Windecker Stephan, Praz Fabien, Lurz Philipp, Hausleiter Jörg, Rudolph Volker. Artificial intelligence-enabled assessment of right ventricular to pulmonary artery coupling in patients undergoing transcatheter tricuspid valve intervention.. European heart journal. Cardiovascular Imaging. 2024. DOI: 10.1093/ehjci/jead324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.