MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2023.08.047

Медицинская библиотека · JACC. Cardiovascular interventions · 2023

Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry.

Simonato Matheus, Whisenant Brian K, Unbehaun Axel, Kempfert Jörg, Ribeiro Henrique B, Kornowski Ran, Erlebach Magdalena, Bleiziffer Sabine, Windecker Stephan, Pilgrim Thomas, Tomii Daijiro, Guerrero Mayra, Ahmad Yousif, Forrest John K, Montorfano Matteo, Ancona Marco, Adam Matti, Wienemann Hendrik, Finkelstein Ariel, Villablanca Pedro, Codner Pablo, Hildick-Smith David, Ferrari Enrico, Petronio Anna Sonia, Shamekhi Jasmin, Presbitero Patrizia, Bruschi Giuseppe, Rudolph Tanja, Cerillo Alfredo, Attias David, Nejjari Mohammed, Abizaid Alexandre, Felippi de Sá Marchi Maurício, Horlick Eric, Wijeysundera Harindra, Andreas Martin, Thukkani Arun, Agrifoglio Marco, Iadanza Alessandro, Baer L Matthew, Nanna Michael G, Dvir Danny

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction.

OBJECTIVES

This study aimed to determine whether device position and asymmetry are associated with these outcomes.

METHODS

Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated.

RESULTS

A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027).

CONCLUSIONS

Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.

Для цитирования: Simonato Matheus, Whisenant Brian K, Unbehaun Axel, Kempfert Jörg, Ribeiro Henrique B, Kornowski Ran, Erlebach Magdalena, Bleiziffer Sabine, Windecker Stephan, Pilgrim Thomas, Tomii Daijiro, Guerrero Mayra, Ahmad Yousif, Forrest John K, Montorfano Matteo, Ancona Marco, Adam Matti, Wienemann Hendrik, Finkelstein Ariel, Villablanca Pedro, Codner Pablo, Hildick-Smith David, Ferrari Enrico, Petronio Anna Sonia, Shamekhi Jasmin, Presbitero Patrizia, Bruschi Giuseppe, Rudolph Tanja, Cerillo Alfredo, Attias David, Nejjari Mohammed, Abizaid Alexandre, Felippi de Sá Marchi Maurício, Horlick Eric, Wijeysundera Harindra, Andreas Martin, Thukkani Arun, Agrifoglio Marco, Iadanza Alessandro, Baer L Matthew, Nanna Michael G, Dvir Danny. Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry.. JACC. Cardiovascular interventions. 2023. DOI: 10.1016/j.jcin.2023.08.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.