Аннотация

BACKGROUND

The development of the PASCAL transcatheter valve repair system for treating mitral regurgitation (MR) greatly extends therapeutic options.

AIMS: To assess the safety, efficacy, and time efficiency of the PASCAL system in transcatheter edge-to-edge repair (TEER) under conscious sedation (CS).

METHODS

This is a retrospective, two-center, German registry study consisting of 211 patients who underwent TEER using the PASCAL system under CS. The endpoints were to assess (1) technical, device, and procedural success as per Mitral Valve Academic Research Consortium (MVARC), (2) conversion rate to general anesthesia (GA), (3) hospital length of stay (LoS), (4) New York Heart Association (NYHA) class, and (5) MR compared to baseline at 30-day.

RESULTS

A total of 211 patients with a mean age of 78.4 ± 8.9 years, with 51.4% being female and 86.7% belonging to NYHA functional class III/IV and EuroSCORE II 6.3 ± 4.9%, were enrolled. Procedural success attained was 96.9%, and six patients (2.8%) required conversion from CS to GA. At 30 days follow-up, a significant improvement in MR was found in 96 patients (54.2%) patients with 0/1 grade MR and 45 patients (29.5%) were in NYHA functional class III + IV. Moreover, TEER under CS has a short hospital LoS (6.71 ± 5.29 days) and intensive care unit LoS (1.34 ± 3.49 days) with a 2.8% mortality rate.

CONCLUSIONS

Performing TEER with the PASCAL system under CS resulted in appreciable (96.9%) procedural success with low mortality and is a safe and promising alternative to GA with positive clinical outcomes.

Для цитирования: Geisler Tobias, Schreieck Juergen, Euper Miriam, Zdanyte Monika, Goldschmied Andreas, Gawaz Meinrad, Bramlage Peter, Haurand Jean M, Kelm Malte, Horn Patrick. Outcomes of patients undergoing edge-to-edge mitral valve repair with the Edwards PASCAL transcatheter valve repair system under conscious sedation.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2023. DOI: 10.1002/ccd.30866.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.