MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3904/kjim.2014.189

Медицинская библиотека · The Korean journal of internal medicine · 2015

The efficacy and safety of drug-eluting balloons for the treatment of in-stent restenosis as compared with drug-eluting stents and with conventional balloon angioplasty.

Oh Pyung Chun, Suh Soon Yong, Kang Woong Chol, Lee Kyounghoon, Han Seung Hwan, Ahn Taehoon, Shin Eak Kyun

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Treatment of coronary in-stent restenosis (ISR) is still associated with a high incidence of recurrence. We aimed to compare the efficacy and safety of drug-eluting balloons (DEB) for the treatment of ISR as compared with conventional balloon angioplasty (BA) and drug-eluting stents (DES).

METHODS

Between January 2006 and May 2012 a total of 177 patients (188 lesions, 64.1 ± 11.7 years old) who underwent percutaneous coronary intervention for ISR were retrospectively enrolled. Clinical outcomes were compared between patients treated with DEB (n = 58, 32.8%), conventional BA (n = 65, 36.7%), or DES (n = 54, 30.5%). The primary end point was a major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction, and target lesion revascularization(TLR).

RESULTS

Baseline characteristics were not different except for a history of previous MI, which was more frequent in patients treated by conventional BA or DES than in patients treated by DEB (40.0% vs. 48.1% vs. 17.2%, respectively, p = 0.002). The total incidences of MACEs were 10.7%, 7.4%, and 15.4% in patients treated by DEB, DES, or conventional BA, respectively (p > 0.05). TLR was more frequent in patients treated by conventional BA than in patients treated by DEB or DES, but this was not statistically significant (10.8% vs. 6.9% vs. 3.7%, p > 0.05 between all group pairs, respectively).

CONCLUSIONS

This study showed that percutaneous coronary intervention using DEB might be a feasible alternative to conventional BA or DES implantation for treatment of coronary ISR. Further large-scaled, randomized study assessing long-term clinical and angiographic outcomes will be needed.

Для цитирования: Oh Pyung Chun, Suh Soon Yong, Kang Woong Chol, Lee Kyounghoon, Han Seung Hwan, Ahn Taehoon, Shin Eak Kyun. The efficacy and safety of drug-eluting balloons for the treatment of in-stent restenosis as compared with drug-eluting stents and with conventional balloon angioplasty.. The Korean journal of internal medicine. 2015. DOI: 10.3904/kjim.2014.189.