MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2023.09.010

Медицинская библиотека · Journal of cardiology · 2023

Initial results of transcatheter modification of left atrial appendage by obliteration with device in patients with nonvalvular atrial fibrillation: Real-world data from the TERMINATOR registry.

Hara Hidehiko, Kubo Shunsuke, Nakajima Yoshifumi, Matsumoto Takashi, Kondo Yusuke, Sugane Hiroki, Okubo Kenji, Nakagawa Koji, Nagatomo Daisuke, Hachinohe Daisuke, Kusa Shigeki, Goya Masahiko, Nanasato Mamoru, Arita Takeshi, Yamasaki Hiro, Kuwabara Kensuke, Yoshiyama Tomotaka, Tanaka Nobuaki, Masuda Masaharu, Sakamoto Tomohiro, Nakashima Masaki, Ohno Yohei, Saito Shigeru, Fukunaga Masato

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Percutaneous left atrial appendage closure (LAAC) has increased for those who need alternative to long-term anticoagulation with non-valvular atrial fibrillation (NVAF).

METHODS AND

RESULTS

From September 2019, after initiating WATCHMAN (Boston Scientific, Maple Grove, MN, USA) device implantation, we established Transcatheter Modification of Left Atrial Appendage by Obliteration with Device in Patients from the NVAF (TERMINATOR) registry. Utilizing 729 patients' data until January 2022, we analyzed percutaneous LAAC data regarding this real-world multicenter prospective registry. A total of 729 patients were enrolled. Average age was 74.9 years and 28.5 % were female. Paroxysmal AF was 37.9 % with average CHADS2 3.2, CHA2DS2-VASc 4.7, and HAS-BLED score of 3.4. WATCHMAN implantation was successful in 99.0 %. All-cause deaths were 3.2 %, and 1.2 % cardiovascular or unexplained deaths occurred during follow-up [median 222, interquartile range (IQR: 93-464) days]. Stroke occurred in 2.2 %, and the composite endpoint which included cardiovascular or unexplained death, stroke, and systemic embolism were counted as 3.4 % [median 221, (IQR: 93-464) days]. Major bleeding defined as BARC type 3 or 5 was seen in 3.7 %, and there was 8.6 % of all bleeding events in total [median 219, (IQR: 93-464) days].

CONCLUSIONS

These preliminary data demonstrated percutaneous LAAC with WATCHMAN device might have a potential to reduce stroke and bleeding events for patients with NVAF. Further investigation is mandatory to confirm the long-term results of this strategy using this transcatheter local therapy instead of life-long systemic anticoagulation.

Для цитирования: Hara Hidehiko, Kubo Shunsuke, Nakajima Yoshifumi, Matsumoto Takashi, Kondo Yusuke, Sugane Hiroki, Okubo Kenji, Nakagawa Koji, Nagatomo Daisuke, Hachinohe Daisuke, Kusa Shigeki, Goya Masahiko, Nanasato Mamoru, Arita Takeshi, Yamasaki Hiro, Kuwabara Kensuke, Yoshiyama Tomotaka, Tanaka Nobuaki, Masuda Masaharu, Sakamoto Tomohiro, Nakashima Masaki, Ohno Yohei, Saito Shigeru, Fukunaga Masato. Initial results of transcatheter modification of left atrial appendage by obliteration with device in patients with nonvalvular atrial fibrillation: Real-world data from the TERMINATOR registry.. Journal of cardiology. 2023. DOI: 10.1016/j.jjcc.2023.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.