MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2023.1233093

Медицинская библиотека · Frontiers in cardiovascular medicine · 2023

Automatic image-based tracking of gadolinium-filled balloon wedge catheters for MRI-guided cardiac catheterization using deep learning.

Neofytou Alexander Paul, Kowalik Grzegorz Tomasz, Vidya Shankar Rohini, Huang Li, Moon Tracy, Mellor Nina, Razavi Reza, Neji Radhouene, Pushparajah Kuberan, Roujol Sébastien

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Magnetic Resonance Imaging (MRI) is a promising alternative to standard x-ray fluoroscopy for the guidance of cardiac catheterization procedures as it enables soft tissue visualization, avoids ionizing radiation and provides improved hemodynamic data. MRI-guided cardiac catheterization procedures currently require frequent manual tracking of the imaging plane during navigation to follow the tip of a gadolinium-filled balloon wedge catheter, which unnecessarily prolongs and complicates the procedures. Therefore, real-time automatic image-based detection of the catheter balloon has the potential to improve catheter visualization and navigation through automatic slice tracking.

METHODS

In this study, an automatic, parameter-free, deep-learning-based post-processing pipeline was developed for real-time detection of the catheter balloon. A U-Net architecture with a ResNet-34 encoder was trained on semi-artificial images for the segmentation of the catheter balloon. Post-processing steps were implemented to guarantee a unique estimate of the catheter tip coordinates. This approach was evaluated retrospectively in 7 patients (6M and 1F, age = 7 ± 5 year) who underwent an MRI-guided right heart catheterization procedure with all images acquired in an orientation unseen during training.

RESULTS

The overall accuracy, specificity and sensitivity of the proposed catheter tracking strategy over all 7 patients were 98.4 ± 2.0%, 99.9 ± 0.2% and 95.4 ± 5.5%, respectively. The computation time of the deep-learning-based segmentation step was ∼10 ms/image, indicating its compatibility with real-time constraints.

CONCLUSION

Deep-learning-based catheter balloon tracking is feasible, accurate, parameter-free, and compatible with real-time conditions. Online integration of the technique and its evaluation in a larger patient cohort are now warranted to determine its benefit during MRI-guided cardiac catheterization.

Для цитирования: Neofytou Alexander Paul, Kowalik Grzegorz Tomasz, Vidya Shankar Rohini, Huang Li, Moon Tracy, Mellor Nina, Razavi Reza, Neji Radhouene, Pushparajah Kuberan, Roujol Sébastien. Automatic image-based tracking of gadolinium-filled balloon wedge catheters for MRI-guided cardiac catheterization using deep learning.. Frontiers in cardiovascular medicine. 2023. DOI: 10.3389/fcvm.2023.1233093.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.