Diagnostic Performance of Cardiac Computed Tomography for Detecting Patent Foramen Ovale: Evaluation Using Transesophageal Echocardiography and Catheterization as Reference Standards.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Miki Takashi, Nakagawa Koji, Ichikawa Keishi, Mizuno Tomofumi, Nakayama Rie, Ejiri Kentaro, Kawada Satoshi, Takaya Yoichi, Miyamoto Masakazu, Miyoshi Toru, Akagi Teiji, Ito Hiroshi

Аннотация

BACKGROUND: Patent foramen ovale (PFO) is associated with various diseases such as cryptogenic stroke, migraine, and platypnea-orthodeoxia syndrome. This study aimed to evaluate the diagnostic performance of cardiac computed tomography (CT) for PFO detection.

MATERIALS AND METHODS: Consecutive patients diagnosed with atrial fibrillation and who underwent catheter ablation with pre-procedural cardiac CT and transesophageal echocardiography (TEE) were enrolled in this study. The presence of PFO was defined as (1) the confirmation of PFO using TEE and/or (2) the catheter crossing the interatrial septum (IAS) into the left atrium during ablation. CT findings indicative of PFO included (1) the presence of a channel-like appearance (CLA) on the IAS and (2) a CLA with a contrast jet flow from the left atrium to the right atrium. The diagnostic performance of both a CLA alone and a CLA with a jet flow was evaluated for PFO detection.

RESULTS: Altogether, 151 patients were analyzed in the study (mean age, 68 years; men, 62%). Twenty-nine patients (19%) had PFO confirmed by TEE and/or catheterization. The diagnostic performance of a CLA alone was as follows: sensitivity, 72.4%; specificity, 79.5%; positive predictive value (PPV), 45.7%; negative predictive value (NPV), 92.4%. The diagnostic performance of a CLA with a jet flow was as follows: sensitivity, 65.5%; specificity, 98.4%; PPV, 90.5%; NPV, 92.3%. The diagnostic performance of a CLA with a jet flow was statistically superior to that of a CLA alone (p = 0.045), and the C-statistics were 0.76 and 0.82, respectively.

CONCLUSION: A CLA with a contrast jet flow in cardiac CT has a high PPV for PFO detection, and its diagnostic performance is superior to that of a CLA alone.