Kodali Susheel K, Hahn Rebecca T, Davidson Charles J, Narang Akhil, Greenbaum Adam, Gleason Patrick, Kapadia Samir, Miyasaka Rhonda, Zahr Firas, Chadderdon Scott, Smith Robert L, Grayburn Paul, Kipperman Robert M, Marcoff Leo, Whisenant Brian, Gonzales Mike, Makkar Raj, Makar Moody, O'Neill William, Wang Dee Dee, Gray William A, Abramson Sandra, Hermiller James, Mitchel Lucas, Lim D Scott, Fowler Dale, Williams Mathew, Pislaru Sorin V, Dahou Abdellaziz, Mack Michael J, Leon Martin B, Eleid Mackram F

Многоцентровое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution.

OBJECTIVES

The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR.

METHODS

Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates.

RESULTS

Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001).

CONCLUSIONS

The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).

Для цитирования: Kodali Susheel K, Hahn Rebecca T, Davidson Charles J, Narang Akhil, Greenbaum Adam, Gleason Patrick, Kapadia Samir, Miyasaka Rhonda, Zahr Firas, Chadderdon Scott, Smith Robert L, Grayburn Paul, Kipperman Robert M, Marcoff Leo, Whisenant Brian, Gonzales Mike, Makkar Raj, Makar Moody, O'Neill William, Wang Dee Dee, Gray William A, Abramson Sandra, Hermiller James, Mitchel Lucas, Lim D Scott, Fowler Dale, Williams Mathew, Pislaru Sorin V, Dahou Abdellaziz, Mack Michael J, Leon Martin B, Eleid Mackram F. 1-Year Outcomes of Transcatheter Tricuspid Valve Repair.. Journal of the American College of Cardiology. 2023. DOI: 10.1016/j.jacc.2023.02.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.