MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.123.012892

Медицинская библиотека · Circulation. Cardiovascular interventions · 2023

Catheter-Induced Postextrasystolic Potentiation in the Assessment of Severity of Low-Gradient Aortic Valve Stenosis.

Dehghani Payam, Singh Jyotpal, Singer Zachary, Booker Jeffrey, Lavoie Andrea J, Zimmermann Rodney H, Shavadia Jay S, Webb John G, Clavel Marie-Annick, Pibarot Philippe

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Deciphering which patients with low-gradient aortic valve disease have severe stenosis can be difficult. We aimed to correlate the postextrasystolic potentiation (PESP) with dobutamine stress echocardiography and multidetector computed tomography in patients with low-gradient aortic valve stenosis.

METHODS

Patients with an aortic valve area ≤1 cm2 and a mean gradient <40 mm Hg were included. Aortic valve stenosis severity was assessed by a core lab with dobutamine stress echocardiography, followed by a multidetector computed tomography aortic valve score if indeterminate. A premature ventricular contraction was induced by intentional catheter contact with the myocardium within the left ventricle. PESP was calculated as a percent change of pre-to-post mean gradient. Multidetector computed tomography was used to measure the aortic valve calcification score, and subsequently, aortic valve calcification density.

RESULTS

Twenty-eight patients (age, 77±10 years; 19 female) were included. Dobutamine stress echocardiography increased mean gradient from baseline of 25±7 mm Hg to 36±11 mm Hg; pre-premature ventricular contraction mean gradient was 25±7 mm Hg and increased to post-premature ventricular contraction mean gradient of 32±10 mm Hg, representing a PESP of 24±11%. A ≥20% in PESP resulted in 100% sensitivity, 77% specificity, 83% positive predictive value, and 100% negative predictive value for diagnosing severe aortic valve stenosis. There was a significant correlation between PESP and projected aortic valve area and aortic valve calcification density (R=-0.64, P=0.0003; R=0.057, P=0.014, respectively).

CONCLUSIONS

In patients with low-gradient aortic valve stenosis, catheter-induced premature ventricular contractions during cardiac catheterization causing ≥20% PESP has a 100% sensitivity for severe aortic valve stenosis. Validation of this 20% cutoff in larger groups with correlation to clinical end points is required.

Для цитирования: Dehghani Payam, Singh Jyotpal, Singer Zachary, Booker Jeffrey, Lavoie Andrea J, Zimmermann Rodney H, Shavadia Jay S, Webb John G, Clavel Marie-Annick, Pibarot Philippe. Catheter-Induced Postextrasystolic Potentiation in the Assessment of Severity of Low-Gradient Aortic Valve Stenosis.. Circulation. Cardiovascular interventions. 2023. DOI: 10.1161/circinterventions.123.012892.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.