Accounting for blood attenuation in intravascular near-infrared fluorescence-ultrasound imaging using a fluorophore-coated guidewire.

Rauschendorfer Philipp, Wissmeyer Georg, Jaffer Farouc A, Gorpas Dimitris, Ntziachristos Vasilis

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Intravascular near-infrared fluorescence (NIRF) imaging aims to improve the inspection of vascular pathology using fluorescent agents with specificity to vascular disease biomarkers. The method has been developed to operate in tandem with an anatomical modality, such as intravascular ultrasound (IVUS), and complements anatomical readings with pathophysiological contrast, enhancing the information obtained from the hybrid examination.

AIM: However, attenuation of NIRF signals by blood challenges NIRF quantification. We propose a new method for attenuation correction in NIRF intravascular imaging based on a fluorophore-coated guidewire that is used as a reference for the fluorescence measurement and provides a real-time measurement of blood attenuation during the NIRF examination.

APPROACH: We examine the performance of the method in a porcine coronary artery ex vivo and phantoms using a 3.2F NIRF-IVUS catheter.

RESULTS

We demonstrate marked improvement over uncorrected signals of up to 4.5-fold and errors of < 11 % for target signals acquired at distances up to 1 mm from the catheter system employed.

CONCLUSIONS

The method offers a potential means of improving the accuracy of intravascular NIRF imaging under in vivo conditions.

Для цитирования: Rauschendorfer Philipp, Wissmeyer Georg, Jaffer Farouc A, Gorpas Dimitris, Ntziachristos Vasilis. Accounting for blood attenuation in intravascular near-infrared fluorescence-ultrasound imaging using a fluorophore-coated guidewire.. Journal of biomedical optics. 2023. DOI: 10.1117/1.jbo.28.4.046001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.