MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2012-302351

Медицинская библиотека · The British journal of ophthalmology · 2013

Previous cyclodestruction is a risk factor for late-onset hypotony and suprachoroidal haemorrhage after glaucoma drainage device surgery.

Rosentreter André, Gaki Stergiani, Lappas Alexandra, Cursiefen Claus, Dietlein Thomas S

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To investigate whether previous cyclodestructive (eg, cyclophotocoagulation and cyclocryodestruction) procedures have any influence on the general outcome and pressure level after glaucoma drainage device (GDD) surgery.

METHODS

Retrospective analysis of 110 consecutive patients who had undergone GDD (Baerveldt 250 mm(2) and 350 mm(2) implant, AMO, USA) surgery with a minimum follow-up of 3 months. The patients were divided into patients with previous cyclodestructive surgery before GDD surgery (I; 47 patients) and patients without previous cyclodestructive surgery (II; 63 patients). Intraocular pressure (IOP), medication score, best-corrected visual acuity and surgical treatments were recorded before and after drainage device implantation.

RESULTS

Patients of group I had a mean preoperative IOP of 32.1 mm Hg and a mean medication score of 4.8; patients of group II had a mean preoperative IOP of 29.2 mm Hg (p=0.18) and a mean medication score of 4.9 (p=0.84). All patients who developed suprachoroidal haemorrhage (six cases) belonged to group I (6/47=12.8%), no patient of group II (0/63=0%) developed suprachoroidal haemorrhage (Fisher's test: p=0.01). Twelve patients developed late-onset (>6 weeks after GDD surgery) hypotony, nine of them belonging to group I (9/47=19.1%) and three of them to group II (3/63=4.8%) (Fisher's test: p=0.03).

CONCLUSIONS

While taking potential bias arising from the retrospective nature of the study into consideration, a history of previous cyclodestructive procedures before GDD surgery seems to be a major risk factor for suprachoroidal haemorrhage and for late-onset postoperative hypotony.

Для цитирования: Rosentreter André, Gaki Stergiani, Lappas Alexandra, Cursiefen Claus, Dietlein Thomas S. Previous cyclodestruction is a risk factor for late-onset hypotony and suprachoroidal haemorrhage after glaucoma drainage device surgery.. The British journal of ophthalmology. 2013. DOI: 10.1136/bjophthalmol-2012-302351.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.