MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurjcn/zvad003

Медицинская библиотека · European journal of cardiovascular nursing · 2023

Amiodarone-induced phlebitis: incidence and adherence to a clinical practice guideline.

Brørs Gunhild, Gjeilo Kari Hanne, Lund Tonje, Skevik Karin, Aa Elizabeth, Høvik Lise Husby, Skarsvaag Torhild, Mjølstad Ole Christian

Наблюдательное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Intravenous amiodarone is an irritant of peripheral blood vessels with phlebitis as an adverse effect. The aims were to determine the incidence of intravenous amiodarone-induced phlebitis, to describe adherence to a clinical practice guideline, and to determine how characteristics were distributed between those with and without phlebitis.

METHODS AND

RESULTS

A prospective observational study was conducted. Adult patients treated with amiodarone through a peripheral intravenous catheter (PIVC) or a central venous catheter were included. PIVC characteristics were measured using the PIVC mini questionnaire. Patients with ≥two signs of phlebitis were categorized as having phlebitis. Adherence to the clinical practice guideline was registered on a standard abstract sheet. Data were collected from the amiodarone start-up to 2 days after the amiodarone was discontinued. In total, 124 patients with amiodarone infusions were observed, of which 69% were administered via a PIVC. The phlebitis rate was 44%. Fifty-three per cent developed amiodarone-induced phlebitis during the infusion phase, while 47% presented phlebitis during the post-infusion phase. The three most observed signs or symptoms of phlebitis were redness (87%), pain (81%), and swelling (71%). The most commonly used PIVC site was the elbow, and 35% of the PIVCs were large (18 gauge), which was the last preferred site and size according to the clinical practice guideline.

CONCLUSION

A large proportion of the patients developed amiodarone-induced phlebitis. The adherence to the clinical practice guideline was not optimal according to the PIVC recommendations. Prevention of amiodarone-induced phlebitis should have high priority to reduce patient harm.

Для цитирования: Brørs Gunhild, Gjeilo Kari Hanne, Lund Tonje, Skevik Karin, Aa Elizabeth, Høvik Lise Husby, Skarsvaag Torhild, Mjølstad Ole Christian. Amiodarone-induced phlebitis: incidence and adherence to a clinical practice guideline.. European journal of cardiovascular nursing. 2023. DOI: 10.1093/eurjcn/zvad003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.