MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hroo.2022.08.001

Медицинская библиотека · Heart rhythm O2 · 2022

Safety of continuous left atrial phased-array intracardiac echocardiography during left atrial ablation for atrial fibrillation.

Jackson Larry R, Holmqvist Fredrik, Parish Alice, Green Cynthia L, Piccini Jonathan P, Bahnson Tristram D

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein (PV) isolation using radiofrequency ablation (RFA) to treat atrial fibrillation (AF) requires delivery of contiguous transmural lesions at the PV antra while avoiding injury to the esophagus. Continuous 2-dimensional phased-array intracardiac echocardiography (ICE) from within the left atrium (LA) can provide consistent high-resolution images of catheter tip contact and location during ablation.

OBJECTIVE

The purpose of this study was to compare near-term safety outcomes of therapeutic AF ablation with and without ICE imaging from within the LA.

METHODS

The study cohort included 590 consecutive patients undergoing RFA for AF including continuous ICE imaging during ablation from within either the right atrium (RA) or the LA. Subjects were followed prospectively, and periprocedural complications within 30 days were identified and recorded.

RESULTS

All subjects had RA ICE imaging to guide transseptal catheterization. Ultrasound imaging from both RA and LA was used in 243 (41.2%). Respectively, the LA vs RA only imaging cohorts were comparable with respect to age (median 64 [interquartile range 57.4-71.2] years vs 64 [56.2-70.6] years; P = .425); history of hypertension (64.0% vs 67.2%; P = .421); diabetes mellitus (23.1% vs 19.4%; P = .268); previous cerebrovascular accident/transient ischemic attack (10.8% vs 8.4%; P = .331); and AF type (P = .241). There were no significant differences in major complications within 30 days between the 2 cohorts (P = .649) and no identified cases of esophageal or phrenic nerve injury or PV stenosis.

CONCLUSIONS

Routine continuous LA ICE imaging seems to be safe and holds potential to facilitate lesion delivery during RFA for AF.

Для цитирования: Jackson Larry R, Holmqvist Fredrik, Parish Alice, Green Cynthia L, Piccini Jonathan P, Bahnson Tristram D. Safety of continuous left atrial phased-array intracardiac echocardiography during left atrial ablation for atrial fibrillation.. Heart rhythm O2. 2022. DOI: 10.1016/j.hroo.2022.08.001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.