MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2022.08.034

Медицинская библиотека · JACC. Cardiovascular interventions · 2022

Evaluation of Multimodality LAA Leak Closure Methods Following Incomplete Occlusion: The LAA Leak Study.

Charate Rishi, Ahmed Adnan, Della Rocca Domenico G, Bloom Stephen, Garg Jalaj, Pothineni Naga Venkata K, DiBiase Luigi, Turagam Mohit, Gopinathannair Rakesh, Horton Rodney, Kar Saibal, Fontana Gregory, Doshi Shephal K, Swarup Vijay, Finn Aloke, Reddy Vivek, Natale Andrea, Lakkireddy Dhanunjaya

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Incomplete left atrial appendage (LAA) closure is an evolving topic of clinical significance and thromboembolic potential, with recent long-term studies suggesting lower cutoffs for relevant leak size.

OBJECTIVES

The aim of this prospective observational study was to assess 3 different closure techniques for persistent peridevice leaks after incomplete LAA closure and compare their efficacy and safety outcomes.

METHODS

We studied 160 patients (mean age 72 ± 9 years; 71% men) who underwent 1 of the 3 available modalities (detachable embolization coils, vascular plugs or septal occluders, and radiofrequency ablation) for residual central or eccentric leak closure. Both acute postprocedural success (closure or <1-mm leak at the end of the procedure) and closure at 1-year follow-up transesophageal echocardiography imaging were evaluated.

RESULTS

Of 160 patients, 0.6%, 41.3%, and 58.1% had mild (1-2 mm), moderate (3-5 mm), and severe (≥5 mm) leaks, respectively. Baseline LAA closure type was 72.5% Watchman FLX, 16.3% Lariat, 5.6% surgical ligation, 1.9% AtriClip, and 1.9% Amulet. Successful closure (0- or <1-mm leak) was seen in 100% of patients in all cohorts following intervention, with overall complete closure (0-1 mm) or mild or minimal leaks (1-2 mm) on 1-year follow-up transesophageal echocardiography seen in 100% of the atrial septal occluder or vascular plug cohort, 85.9% of the coil cohort, and 83.3% of the radiofrequency ablation cohort (P < 0.001). Two patients (1.3%) experienced cardiac tamponade, and there were no deaths or other complications.

CONCLUSIONS

Peridevice leaks can safely and effectively be closed using 3 different modalities depending on size and location.

Для цитирования: Charate Rishi, Ahmed Adnan, Della Rocca Domenico G, Bloom Stephen, Garg Jalaj, Pothineni Naga Venkata K, DiBiase Luigi, Turagam Mohit, Gopinathannair Rakesh, Horton Rodney, Kar Saibal, Fontana Gregory, Doshi Shephal K, Swarup Vijay, Finn Aloke, Reddy Vivek, Natale Andrea, Lakkireddy Dhanunjaya. Evaluation of Multimodality LAA Leak Closure Methods Following Incomplete Occlusion: The LAA Leak Study.. JACC. Cardiovascular interventions. 2022. DOI: 10.1016/j.jcin.2022.08.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.