Single-Center Experience With a Self-Expandable Venous Cannula During Minimally Invasive Cardiac Surgery.

Van Praet Karel M, Kofler Markus, Meyer Alexander, Sündermann Simon H, Hommel Matthias, Falk Volkmar, Kempfert Jörg

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Venous drainage is often problematic in minimally invasive cardiac surgery (MICS). Here, we describe our experience with a self-expandable stent cannula designed to optimize venous drainage.

METHODS

The smart canula® was used in 58 consecutive patients undergoing MICS for mitral valve disease (n = 40), left atrial myxoma (n = 3), left ventricular outflow tract obstruction (n = 1), and aortic valve replacement via a right anterior minithoracotomy (n = 14) procedures. The venous cannula was placed under transesophageal echocardiography guidance to reach the superior vena cava. Vacuum-assisted venous drainage (between -20 and -35 mm Hg) was used to reach a target flow index of 2.2 L/min/m² at a core temperature of 34 °C using a goal-directed perfusion strategy aimed at a minimum DO2 of 272 mL/min/m2. Cardiopulmonary bypass (CPB) parameters were recorded, and hemolysis-related parameters were analyzed on postoperative days 1 to 7.

RESULTS

Mean body surface area and median body mass index were 1.9 ± 0.2 m2 and 25.2 (23.4, 30.2) kg/m2. Mean CPB and median cross-clamping times were 107.7 ± 24.4 min and 64.5 (53, 75.8) min, and median CPB flow during cardioplegic arrest was 4 (3.6, 4.2) L/min (median cardiac index 2.1 [2, 2.2] L/min/m²). Venous drainage was considered sufficient by the surgeon in all cases, and insertion and removal were uncomplicated. Mean SvO2 during CPB was 80.2% ± 5.5%, and median peak lactate was 10 (8, 14) mg/dL, indicating sufficient perfusion. Mean venous negative drainage pressure during cross-clamping was 27.2 ± 12.3 mm Hg. Platelets dropped by 73.6 ± 37.5 K/µL, lactate dehydrogenase rose by 81.5 (44.3, 140.8) U/L, and leukocytes rose by 3.4 (2.2, 7.2) K/µL on postoperative day 1.

CONCLUSIONS

The venous smart canula® allows for optimal venous drainage at low negative drainage pressures, facilitating sufficient perfusion in MICS.

Для цитирования: Van Praet Karel M, Kofler Markus, Meyer Alexander, Sündermann Simon H, Hommel Matthias, Falk Volkmar, Kempfert Jörg. Single-Center Experience With a Self-Expandable Venous Cannula During Minimally Invasive Cardiac Surgery.. Innovations (Philadelphia, Pa.). 2022. DOI: 10.1177/15569845221131534.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.