MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3349/ymj.2012.53.1.83

Медицинская библиотека · Yonsei medical journal · 2012

Early experience using a left atrial appendage occlusion device in patients with atrial fibrillation.

Kim Yung Ly, Joung Boyoung, On Young Keun, Shim Chi Young, Lee Moon Hyoung, Kim Young-Hoon, Pak Hui-Nam

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Atrial fibrillation (AF) is one of the major risk factors for ischemic stroke, and 90% of thromboembolisms in these patients arise from the left atrial appendage (LAA). Recently, it has been documented that an LAA occlusion device (OD) is not inferior to warfarin therapy, and that it reduces mortality and risk of stroke in patients with AF.

MATERIALS AND

METHODS

We implanted LAA-ODs in 5 Korean patients (all male, 59.8 ± 7.3 years old) with long-standing persistent AF or permanent AF via a percutaneous trans-septal approach.

RESULTS

1) The major reasons for LAA-OD implantation were high risk of recurrent stroke (80%), labile international neutralizing ratio with hemorrhage (60%), and 3/5 (60%) patients had a past history of failed cardioversion for rhythm control. 2) The mean LA size was 51.3 ± 5.0 mm and LAA size was 25.1 × 30.1 mm. We implanted the LAA-OD (28.8 ± 3.4 mm device) successfully in all 5 patients with no complications. 3) After eight weeks of anticoagulation, all patients switched from warfarin to anti-platelet agent after confirmation of successful LAA occlusion by trans-esophageal echocardiography.

CONCLUSION

We report on our early experience with LAA-OD deployment in patients with 1) persistent or permanent AF who cannot tolerate anticoagulation despite significant risk of ischemic stroke, or 2) recurrent stroke in patients who are unable to maintain sinus rhythm.

Для цитирования: Kim Yung Ly, Joung Boyoung, On Young Keun, Shim Chi Young, Lee Moon Hyoung, Kim Young-Hoon, Pak Hui-Nam. Early experience using a left atrial appendage occlusion device in patients with atrial fibrillation.. Yonsei medical journal. 2012. DOI: 10.3349/ymj.2012.53.1.83.