Boston type 1 keratoprosthesis: the CHUM experience.

Robert Marie-Claude, Harissi-Dagher Mona

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the characteristics, indications, complications, and outcomes of the patients who underwent Boston type 1 keratoprosthesis (KPro) surgery at the Université de Montréal affiliated Notre-Dame Hospital.

DESIGN

Retrospective case series.

PARTICIPANTS

Forty-seven eyes of 43 patients who underwent KPro surgery.

METHODS

The charts of all patients who underwent KPro surgery at Notre-Dame Hospital between October 2008 and February 2010 were retrospectively reviewed. Preoperative, intraoperative, and postoperative parameters were collected and analyzed.

RESULTS

The indication for Boston type 1 KPro was corneal graft failure in 27 eyes; 20 eyes had KPro as a primary procedure. Preoperative diagnoses included aniridia (34%), mechanical trauma (11%), infections (9%), surgery-related bullous keratopathy (9%), chemical burns (9%), corneal dystrophies (9%), and Stevens-Johnson syndrome (2%). A known history of glaucoma was present in 36 eyes (77%). Median preoperative best-corrected visual acuity (BCVA) was hand motion (range, 20/100 to light perception). The assembly of the KPro and surgery were uneventful in all cases. Mean follow-up was 10±5 months. MedianBCVA at last follow-up was 20/150 (range, 20/30 to no light perception). The device retention rate was 100% at the end of the follow-up period. Postoperative complications included retroprosthetic membrane in 12 eyes (26%) and glaucoma progression in 11 eyes (23%).

CONCLUSIONS

Our study demonstrates an excellent retention rate of the Boston type 1 KPro and an improvement of BCVA in the majority of patients. Many patients undergoing KPro surgery have ocular comorbidities that require ongoing care to prevent further vision loss following KPro surgery.

Для цитирования: Robert Marie-Claude, Harissi-Dagher Mona. Boston type 1 keratoprosthesis: the CHUM experience.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2011. DOI: 10.3129/i10-103.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.