MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30396

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Radiation reduction in a modern catheterization laboratory: A single-center experience.

Shekhar Shashank, Ajay Abhishek, Agrawal Ankit, Kumar Anirudh, Kaur Manpreet, Isogai Toshiaki, Saad Anas, Abushouk Abdelrahman I, Abdelfattah Omar, Lak Hassan, Farwati Medhat, Ahuja Keerat, Verma Beni R, Wunderle Kevin, Ellis Stephen, Khatri Jaikirshan, Ziada Khaled, Krishnaswamy Amar, Kapadia Samir

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Measures were undertaken at the Cleveland Clinic to reduce radiation exposure to patients and personnel working in the catheterization laboratories. We report our experience with these improved systems over a 7-year period in patients undergoing diagnostic catheterization (DC) and percutaneous coronary interventions (PCIs).

METHODS

Patients were categorized into preinitiative (2009-2012) and postinitiative (2013-2019) groups in the DC and PCI cohorts. Propensity score matching was done between the pre- and postinitiative groups for both cohorts based on age, sex, body surface area, total fluoroscopy time, and total acquisition time. The effectiveness of radiation reduction measures was assessed by comparing the total air kerma (Ka,r ), and fluoroscopy- and acquisition-mode air kerma in patients in the two groups.

RESULTS

In the DC cohort, there was a significant reduction in Ka,r in the postinitiative group in comparison to the preinitiative group (median, 396 vs. 857 mGy; p < 0.001). In the PCI cohort, Ka,r in the postinitiative group was 1265 mGy, which was significantly lower than the corresponding values in the preinitiative group (1994 mGy; p < 0.001). We also observed a significant reduction in fluoroscopy- and acquisition-based air kerma rates, and air kerma area product in the postinitiative group in comparison to the preinitiative group in both matched and unmatched DC and PCI cohorts after the institution of radiation reduction measures.

CONCLUSION

There was a significant and sustained reduction in radiation exposure to patients in the catheterization laboratory with the implementation of advanced protocols. Similar algorithms can be applied in other laboratories to achieve a similar reduction in radiation exposure.

Для цитирования: Shekhar Shashank, Ajay Abhishek, Agrawal Ankit, Kumar Anirudh, Kaur Manpreet, Isogai Toshiaki, Saad Anas, Abushouk Abdelrahman I, Abdelfattah Omar, Lak Hassan, Farwati Medhat, Ahuja Keerat, Verma Beni R, Wunderle Kevin, Ellis Stephen, Khatri Jaikirshan, Ziada Khaled, Krishnaswamy Amar, Kapadia Samir. Radiation reduction in a modern catheterization laboratory: A single-center experience.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2022. DOI: 10.1002/ccd.30396.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.