MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2022.06.046

Медицинская библиотека · The American journal of cardiology · 2022

Ultrasound-Guided Versus Conventional MANTA Vascular Closure Device Deployment After Transcatheter Aortic Valve Implantation.

Miyashita Hirokazu, Moriyama Noriaki, Dahlbacka Sebastian, Vähäsilta Tommi, Vainikka Tiina, Jalanko Mikko, Viikilä Juho, Laine Mika

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Despite the development of device technology and operators' experience, access site vascular complications (VCs) remain one of the major concerns after transcatheter aortic valve implantation (TAVI). MANTA (Teleflex, Wayne, Pennsylvania) is a large-bore vascular closure device (VCD) with promising incidence of VC. Previously, we demonstrated that the ultrasound-guided MANTA (US-MANTA) technique further improved the outcomes compared with conventional MANTA (C-MANTA) without ultrasound guidance. The present study was established to prove the effectiveness of the technique in a larger population. In this study, we included 1,150 patients (335 patients with C-MANTA and 815 with US-MANTA) who received MANTA after TAVI from April 2017 to September 2021. The primary endpoint was MANTA-related VC. Overall VC, VCD failure, and bleeding complications were also assessed based on the Valve Academic Research Consortium 3 criteria. MANTA-related VC occurred in 12.5% in the C-MANTA group and 6.8% in the US-MANTA group (p = 0.001). VCD failure rate were 7.5% and 3.9%, respectively (p = 0.012). Valve Academic Research Consortium 3 major and minor VC were more frequent in C-MANTA group (major: 7.8% vs 4.4%, p = 0.023; minor: 8.1% vs 4.4%, p = 0.022). Multivariate analysis revealed US-MANTA as the negative predictor of MANTA-related VC (odds ratio 0.57, 95% confidence interval 0.36 to 0.89, p = 0.013). However, subgroup analysis showed the efficacy of the US-MANTA technique was limited to the patients without severely calcified puncture site (Pinteraction = 0.048). In conclusion, the US-MANTA technique was an effective strategy to reduce VC after transfemoral TAVI compared with C-MANTA.

Для цитирования: Miyashita Hirokazu, Moriyama Noriaki, Dahlbacka Sebastian, Vähäsilta Tommi, Vainikka Tiina, Jalanko Mikko, Viikilä Juho, Laine Mika. Ultrasound-Guided Versus Conventional MANTA Vascular Closure Device Deployment After Transcatheter Aortic Valve Implantation.. The American journal of cardiology. 2022. DOI: 10.1016/j.amjcard.2022.06.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.