MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.30250

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Robotically performed diagnostic coronary angiography.

Joseph Timothy, VanOosterhout Stacie, Negash Araya, VanLoo Lisa, Redmond Meaghan, Parker Jessica L, McNamara David A, Madder Ryan D

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study was performed to investigate the efficacy and safety of robotic diagnostic coronary angiography.

BACKGROUND

Robotic percutaneous coronary intervention is associated with marked reductions in physician radiation exposure. Development of robotic diagnostic coronary angiography might similarly impact occupational safety.

METHODS

Stable patients referred for coronary angiography were prospectively enrolled. After obtaining vascular access, diagnostic catheters were manually advanced over a wire to the ascending aorta. All subsequent catheter movements were performed robotically. The primary endpoint was procedural success, defined as robotic completion of coronary angiography without conversion to a manual procedure and the absence of procedural major adverse cardiovascular events (MACE-cardiac death, cardiac arrest, or stroke) and major angiographic complications (coronary/aortic dissection or embolization). The primary hypothesis was that the observed rate of the primary endpoint, evaluated at the completion of coronary angiography, would meet a pre-specified performance goal of 74.5%.

RESULTS

Among 46 consecutive patients (age 67 ± 12 years; 69.6% male), diagnostic coronary angiography was completed robotically in all cases without the need for manual conversion and without any MACE or major angiographic complications. Thus, procedural success was 100%, which was significantly higher than the pre-specified performance goal (p < 0.001). Robotic coronary angiography was completed using 2 [2, 3] catheters per case with a median procedural time of 15 [11, 20] minutes.

CONCLUSIONS

Robotic diagnostic coronary angiography was performed with 100% procedural success and no observed complications. These results support the performance of future studies to further explore robotic coronary angiography.

Для цитирования: Joseph Timothy, VanOosterhout Stacie, Negash Araya, VanLoo Lisa, Redmond Meaghan, Parker Jessica L, McNamara David A, Madder Ryan D. Robotically performed diagnostic coronary angiography.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2022. DOI: 10.1002/ccd.30250.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.