Central Line Access for Hemodialysis Adversely Affects Ipsilateral Arteriovenous Graft Outcomes.

Otoya Diana, Simmonds Alexander, Lavingia Kedar, Amendola Michael F

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Central venous stenosis is a common problem that diminishes vascular access lifespan. Current national guidelines recommend that central catheters and arteriovenous grafts (AVGs) be placed contralateral to an existing hemodialysis access. We set forth to delineate any clinically significant outcomes based on laterality in patients undergoing AVG placement with an existing central catheter for dialysis treatments.

METHODS

Using a Veterans Administration Hospital dialysis access database over a four-year period (May 2014 to April 2018), we identified all patients who underwent AVG placement in an upper extremity with an existing ipsilateral (Ipsi-CL) or contralateral (Contra-CL) central line for hemodialysis. AVG outcomes examined included successful cannulation, functional patency, thrombosis events, and endovascular interventions per access site. Clinical records were also examined for location of AVG, arteriovenous fistula or AVG precursors, prior central line placement, peripherally inserted central catheter, and cardiac venous access. All outcomes were followed until July 2021. Student's t-test, Fisher's exact test, and multivariable analysis were used.

RESULTS

A total of 71 AVGs: 55 (77%) were placed contralateral to existing central venous catheters and 16 (23%) were placed on the ipsilateral side. Baseline characteristics between the two groups were not found to be significantly different. This included a history of hypertension, smoking history, prior arteriovenous access, body mass index, race, glucose, creatinine, blood urea nitrogen, hemoglobin, mean corpuscular volume, platelet count, antiplatelet agent, and anticoagulation. 100% (n = 16) of patients in the Ipsi-CL group had previous central venous access compared to 49.1% (n = 27) in Contra-CL (P = <0.001). The mean functional patency for AVG with Contra-CL was 724.78 ± 593.98 days compared to AVGs with Ipsi-CL with mean days of 350.94 ± 431.23 days (P = 0.001). A history of previous central venous catheterization and graft on ipsilateral side of a catheter at the time of surgery was associated with decreased functional duration of graft (odds ratio, 0.25; P = 0.03).

CONCLUSIONS

Within this cohort of patients that underwent AVG, we noted a statistically significant decrease in the duration of functional patency of grafts ipsilateral to central venous catheters. We did not find a difference in cannulation rates, thrombosis events, or overall endovascular interventions. Ipsilateral central access appears to be associated with decreased functional patency of AVGs. These findings highlight a discrepancy that is potentially clinically relevant and further studies are warranted.

Для цитирования: Otoya Diana, Simmonds Alexander, Lavingia Kedar, Amendola Michael F. Central Line Access for Hemodialysis Adversely Affects Ipsilateral Arteriovenous Graft Outcomes.. Annals of vascular surgery. 2022. DOI: 10.1016/j.avsg.2022.04.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.