Computational fluid dynamics analysis of endoluminal aortic perfusion.

Malinowski Daniel, Fournier Yvan, Horbach Andreas, Frick Michael, Magliani Mirko, Kalverkamp Sebastian, Hildinger Martin, Spillner Jan, Behbahani Mehdi, Hima Flutura

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions.

METHODS

An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch.

RESULTS

For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume.

CONCLUSIONS

In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.

Для цитирования: Malinowski Daniel, Fournier Yvan, Horbach Andreas, Frick Michael, Magliani Mirko, Kalverkamp Sebastian, Hildinger Martin, Spillner Jan, Behbahani Mehdi, Hima Flutura. Computational fluid dynamics analysis of endoluminal aortic perfusion.. Perfusion. 2022. DOI: 10.1177/02676591221099809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.