Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People.

Li Ke-Jing, Wong Nicky Lok-Yi, Law Man-Ching, Lam Freddy Man-Hin, Wong Hoi-Ching, Chan Tsz-On, Wong Kit-Naam, Zheng Yong-Ping, Huang Qi-Yao, Wong Arnold Yu-Lok, Kwok Timothy Chi-Yui, Ma Christina Zong-Hao

СтатьяПеревод пока не подготовлен

Аннотация

Falls are a prevalent cause of injury among older people. While some wearable inertial measurement unit (IMU) sensor-based systems have been widely investigated for fall risk assessment, their reliability, validity, and identification ability in community-dwelling older people remain unclear. Therefore, this study evaluated the performance of a commercially available IMU sensor-based fall risk assessment system among 20 community-dwelling older recurrent fallers (with a history of ≥2 falls in the past 12 months) and 20 community-dwelling older non-fallers (no history of falls in the past 12 months), together with applying the clinical scale of the Mini-Balance Evaluation Systems Test (Mini-BESTest). The results show that the IMU sensor-based system exhibited a significant moderate to excellent test-retest reliability (ICC = 0.838, p < 0.001), an acceptable level of internal consistency reliability (Spearman's rho = 0.471, p = 0.002), an acceptable convergent validity (Cronbach's α = 0.712), and an area under the curve (AUC) value of 0.590 for the IMU sensor-based receiver-operating characteristic (ROC) curve. The findings suggest that while the evaluated IMU sensor-based system exhibited good reliability and acceptable validity, it might not be able to fully identify the recurrent fallers and non-fallers in a community-dwelling older population. Further system optimization is still needed.

Для цитирования: Li Ke-Jing, Wong Nicky Lok-Yi, Law Man-Ching, Lam Freddy Man-Hin, Wong Hoi-Ching, Chan Tsz-On, Wong Kit-Naam, Zheng Yong-Ping, Huang Qi-Yao, Wong Arnold Yu-Lok, Kwok Timothy Chi-Yui, Ma Christina Zong-Hao. Reliability, Validity, and Identification Ability of a Commercialized Waist-Attached Inertial Measurement Unit (IMU) Sensor-Based System in Fall Risk Assessment of Older People.. Biosensors. 2023. DOI: 10.3390/bios13120998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.