MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/codi.16591

Медицинская библиотека · Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland · 2023

Diagnostic accuracy of water-soluble contrast enema, contrast-enema computed tomography and endoscopy in detecting anastomotic leakage after (Colo) proctectomy: A meta-analysis.

Chierici Andrea, Granieri Stefano, Frontali Alice

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Anastomotic leakage (AL) as a result of creation of a colorectal/anal anastomosis still represents a frequent complication of colorectal surgery, with short- and long-term consequences on postoperative morbidity, quality of life and oncological outcomes. However, early diagnosis of AL may result in improved outcomes. The aims of this study were to evaluate the diagnostic accuracy of water-soluble contrast enema (WSCE), contrast enema computed tomography (CECT) and endoscopy in identifying AL and to identify the diagnostic procedure that is most accurate.

METHODS

A systematic review and meta-analysis of 19 studies accounting for a total of 25 tests reporting diagnostic accuracy estimates was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines up to June 2021. For the diagnostic tests we evaluated the pooled estimates and conducted pairwise comparisons.

RESULTS

For WSCE, the pooled sensitivity was 0.50, the pooled specificity was 0.99 and the area under the curve (AUC) was 0.91. For endoscopy, the pooled sensitivity was 0.69, specificity was 1.00 and AUC was 0.99. The pooled sensitivity and specificity for CECT were 0.89 and 1.00, respectively; the AUC was 0.99. The comparison between CECT and WSCE highlighted a significantly greater sensitivity (p = 0.04) for CECT, whereas no difference was found for specificity. Compared with CECT, endoscopy was not significantly more accurate in terms of either sensitivity or specificity. Endoscopy was found to be significantly more specific than WSCE (p = 0.031) but no difference was found for sensitivity.

CONCLUSION

Water-soluble contrast enema, endoscopy and CECT have an elevated diagnostic accuracy. However, WSCE is less accurate than either endoscopy or CECT. Although greater sensitivity was demonstrated for CECT compared with endoscopy, this was not significant.

Для цитирования: Chierici Andrea, Granieri Stefano, Frontali Alice. Diagnostic accuracy of water-soluble contrast enema, contrast-enema computed tomography and endoscopy in detecting anastomotic leakage after (Colo) proctectomy: A meta-analysis.. Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland. 2023. DOI: 10.1111/codi.16591.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.