MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-020-02600-9

Медицинская библиотека · Abdominal radiology (New York) · 2020

Rectal gas-induced susceptibility artefacts on prostate diffusion-weighted MRI with epi read-out at 3.0 T: does a preparatory micro-enema improve image quality?

Plodeck Verena, Radosa Christoph Georg, Hübner Hans-Martin, Baldus Christian, Borkowetz Angelika, Thomas Christian, Kühn Jens-Peter, Laniado Michael, Hoffmann Ralf-Thorsten, Platzek Ivan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess whether the application of a preparatory micro-enema reduces gas-induced susceptibility artefacts on diffusion-weighted MRI of the prostate.

METHODS

114 consecutive patients who received multiparametric 3 T MRI of the prostate at our institution were retrospectively enrolled. 63 patients self-administered a preparatory micro-enema prior to imaging, and 51 patients underwent MRI without bowel preparation. Two blinded readers independently reviewed the diffusion-weighted sequences regarding gas-induced artefacts. The presence/severity of artefacts was scored ranging from 0 (no artefact) to 3 (severe artefact). A score ≥ 2 was considered a clinically relevant artefact. Maximum rectal width at the level of the prostate was correlated with the administration of a micro-enema. Scores were compared between the scans performed with and without bowel preparation using univariable and multivariable logistic regression, taking into account potential confounding factors (age and prostate volume).

RESULTS

Significantly less artefacts were found on diffusion-weighted sequences after the administration of a micro-enema shortly prior to MR imaging. Clinically relevant artefacts were found in 10% in the patient group after enema, in 41% without enema. If present, artefacts were also significantly less severe. Mean severity score was 0.3 (enema administered) and 1.2 (no enema), and odds ratio was 0.137 (p < 0.0001) in univariable ordinal logistic regression. Inter-observer agreement was excellent (κ 0.801).

CONCLUSION

The use of a preparatory micro-enema prior to 3 T multiparametric prostate MRI significantly reduces both the incidence and severity of gas-induced artefacts on diffusion-weighted sequences and thus improves image quality.

Для цитирования: Plodeck Verena, Radosa Christoph Georg, Hübner Hans-Martin, Baldus Christian, Borkowetz Angelika, Thomas Christian, Kühn Jens-Peter, Laniado Michael, Hoffmann Ralf-Thorsten, Platzek Ivan. Rectal gas-induced susceptibility artefacts on prostate diffusion-weighted MRI with epi read-out at 3.0 T: does a preparatory micro-enema improve image quality?. Abdominal radiology (New York). 2020. DOI: 10.1007/s00261-020-02600-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.