MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejogrb.2015.02.006

Медицинская библиотека · European journal of obstetrics, gynecology, and reproductive biology · 2015

Correlation between three-dimensional rectosonography and magnetic resonance imaging in the diagnosis of rectosigmoid endometriosis: a preliminary study on the first fifty cases.

Philip Charles-André, Bisch Christian, Coulon Agnés, de Saint-Hilaire Pierre, Rudigoz René-Charles, Dubernard Gil

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Deep infiltrating endometriosis (DIE) raises a number of diagnostic and therapeutic problems. Magnetic resonance imaging (MRI), the reference technique in endometriosis, is questioned for posterior pelvic lesions, especially in rectosigmoid locations. In this study, we describe a new technique called three-dimensional rectosonography (3D-RSG), which combines standard transvaginal ultrasonography (TVUS), 3-dimensional (3D) ultrasonography and the use of water for rectal contrast. We also assess the correlation between 3D-RSG and MRI in the diagnosis of rectosigmoid endometriosis.

STUDY

DESIGN

This study included 50 consecutive women with symptoms suggestive of DIE. After colorectal enema, they underwent a gynecological examination and a 3D TVUS during which 120ml of water was injected in the rectosigmoid to improve the performance of the examination. All patients also underwent an MRI and surgery was offered to the patient if there was discordance between the two procedures.

RESULTS

Fifty women underwent 3D-RSG between May and November 2012. All procedures were well tolerated by patients. Two examinations (4%) were stopped for technical reasons. Nineteen rectosigmoid nodules were diagnosed in 18 women (36%). Eighteen of these nodules were also identified on MRI, and one (2%) nodule seen on MRI was not diagnosed by 3D-RSG. In 31 examinations (62%), neither technique identified an intestinal lesion. There was a concordance rate of 96% between the two techniques. Using MRI as the reference technique, 3D-RSG had a sensitivity of 0.95, a specificity of 0.97, a positive predictive values of 0.95, and a negative predictive value of 0.97. There was a 30.3 positive likelihood ratio and a 0.05 negative likelihood ratio.

CONCLUSIONS

3D-RSG seems an interesting new method for diagnosis of rectosigmoid endometriosis and is both feasible and well tolerated. 3D-RSG is highly concordant with MRI in this indication, although further studies are needed to confirm these primary results.

Для цитирования: Philip Charles-André, Bisch Christian, Coulon Agnés, de Saint-Hilaire Pierre, Rudigoz René-Charles, Dubernard Gil. Correlation between three-dimensional rectosonography and magnetic resonance imaging in the diagnosis of rectosigmoid endometriosis: a preliminary study on the first fifty cases.. European journal of obstetrics, gynecology, and reproductive biology. 2015. DOI: 10.1016/j.ejogrb.2015.02.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.