MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apmr.2016.06.008

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2016

Reliability and Validity of Nonradiologic Measures of Forward Flexed Posture in Parkinson Disease.

Nair Prajakta, Bohannon Richard W, Devaney Laurie, Maloney Catherine, Romano Alexis

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To examine the intertester reliability and validity of 5 nonradiologic measures of forward flexed posture in individuals with Parkinson disease (PD).

DESIGN

Cross-sectional observational study.

SETTING

University outpatient facility and community centers.

PARTICIPANTS

Individuals (N=28) with PD with Hoehn and Yahr scores of 1 through 4.

INTERVENTIONS: Not applicable.

MAIN OUTCOME MEASURES: Occiput to wall status, tragus to wall distance, C7 to wall distance, photographically derived trunk flexion angle, and inclinometric kyphosis measure.

RESULTS

Participants were older adults (mean, 69.7±10.6y) with a 14-month to 15-year (mean, 5.9±3.5y) history of PD. Intertester reliability was excellent for all measures (κ=.89 [cued condition] and 1.0 [relaxed condition] for occiput to wall status; intraclass correlation coefficients, .779-.897 for tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure). Convergent validity was supported for all measures by significant correlations between the same measures obtained during relaxed and cued conditions (eg, occiput to wall relaxed and cued) and for most measures by significant correlations between measures obtained under the same condition (eg, occiput to wall cued and tragus to wall cued). Significant correlations between tragus to wall distance, C7 to wall distance, flexion angle, and inclinometric kyphosis measure and the Unified Parkinson Disease Rating Scale item 28 (posture) also supported convergent validity. Significant differences between tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure values under relaxed and cued conditions supported known condition validity. Known group validity was demonstrated by significant differences in tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure obtained from individuals able and individuals unable to touch their occiput to wall when cued to stand tall.

CONCLUSIONS

Tragus to wall distance, C7 to wall distance, and inclinometric kyphosis measure are reliable and valid nonradiologic measures of forward flexed posture in PD.

Для цитирования: Nair Prajakta, Bohannon Richard W, Devaney Laurie, Maloney Catherine, Romano Alexis. Reliability and Validity of Nonradiologic Measures of Forward Flexed Posture in Parkinson Disease.. Archives of physical medicine and rehabilitation. 2016. DOI: 10.1016/j.apmr.2016.06.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.