Медицинская библиотека · Clinical radiology · 2013

UK intussusception audit: a national survey of practice and audit of reduction rates.

Hannon Edward, Williams Rhianydd, Allan Rosemary, Okoye Bruce

Сравнительное исследованиеСтатьяМногоцентровое исследованиеОбзорПеревод пока не подготовлен

Аннотация

AIM: To define current UK reduction practice and the reductions rates achieved.

MATERIALS AND

METHODS

Electronic surveys were sent to radiologists at 26 UK centres. This assessed methods of reduction, equipment, personnel, and protocol usage. Standardized audit proforma were also sent to evaluate all reductions performed in 2011.

RESULTS

Twenty-two of 26 centres (85%) replied. All used air enema under fluoroscopic guidance. Equipment was not standardized but could be broadly categorized into hand-pumped air-supply systems (seven centres) and pressurized air systems (15 centres). Seventeen centres followed a protocol based on British Society of Paediatric Radiologists (BSPR) guidelines. In 21 of the 22 centres a consultant paediatric radiologist led reductions and only 12 centres reported a surgeon being present. Three hundred and ten cases were reported across 22 centres. Cases per centre ranged from 0-31 (median 14). Reduction rates varied from 38-90% (median 71%). The overall perforation rate was 2.5%. Caseload did not significantly correlate with reduction rate, and there was no significant difference between the two types of equipment used. Median reduction rates were 15% higher in centres with a surgeon present at reduction (p < 0.05).

CONCLUSION

Intussusception care in the UK lacks standardization of equipment and personnel involved. National reduction rates are lower than in current international literature. Improved standardization may lead to an improvement in reduction rates and a surgeon should always be present at reduction.

Для цитирования: Hannon Edward, Williams Rhianydd, Allan Rosemary, Okoye Bruce. UK intussusception audit: a national survey of practice and audit of reduction rates.. Clinical radiology. 2013. DOI: 10.1016/j.crad.2013.10.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.