MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jes.2014.64

Медицинская библиотека · Journal of exposure science & environmental epidemiology · 2014

Ultrasonographic measurement of the femoral cartilage thickness in patients with occupational lead exposure.

Yıldızgören Mustafa T, Baki Ali E, Kara Murat, Ekiz Timur, Tiftik Tülay, Tutkun Engin, Yılmaz Hınç, Özçakar Levent

СтатьяПеревод пока не подготовлен

Аннотация

The objective of the present study is to compare distal femoral cartilage thicknesses of patients with occupational lead exposure with those of healthy subjects by using ultrasonography. A total of 48 male workers (a mean age of 34.8±6.8 years and mean body mass index (BMI) of 25.8±3.1 kg/m(2)) with a likely history of occupational lead exposure and age- and BMI-matched healthy male subjects were enrolled. Demographic and clinical characteristics of the patients, that is, age, weight, height, occupation, estimated duration of lead exposure, and smoking habits were recorded. Femoral cartilage thickness was assessed from the midpoints of right medial condyle (RMC), right lateral condyle (RLC), right intercondylar area (RIA), left medial condyle (LMC), left lateral condyle (LLC), and left intercondylar area (LIA) by using ultrasonography. Although the workers had higher femoral cartilage thickness values at all measurement sites when compared with those of the control subjects, the difference reached statistical significance at RLC (P=0.010), LMC (P=0.001), and LIA (P=0.039). There were no correlations between clinical parameters and cartilage-thickness values of the workers. Subjects with a history of lead exposure had higher femoral cartilage thickness as compared with the healthy subjects. Further studies, including histological evaluations, are awaited to clarify the clinical relevance of this increase in cartilage thickness and to explore the long-term follow-up especially with respect to osteoarthritis development.

Для цитирования: Yıldızgören Mustafa T, Baki Ali E, Kara Murat, Ekiz Timur, Tiftik Tülay, Tutkun Engin, Yılmaz Hınç, Özçakar Levent. Ultrasonographic measurement of the femoral cartilage thickness in patients with occupational lead exposure.. Journal of exposure science & environmental epidemiology. 2014. DOI: 10.1038/jes.2014.64.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.