MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-012-9844-z

Медицинская библиотека · Abdominal imaging · 2012

Detection of colorectal tumors with water enema-multidetector row computed tomography.

Soyer Philippe, Sirol Marc, Dray Xavier, Placé Vinciane, Pautrat Karine, Hamzi Lounis, Boudiaf Mourad

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To retrospectively determine the diagnostic capabilities of water enema-multidetector row computed tomography (WE-MDCT) in the detection of colorectal tumors.

MATERIALS AND

METHODS

One hundred and one patients (55 male, 46 female) who had WE-MDCT and videocolonoscopy because of suspected colorectal tumors were included. Results of complete videocolonoscopy, surgery, and histopathologic analysis were used as standard of reference. Sensitivity, specificity, and accuracy, and positive and negative predictive values of WE-MDCT for the diagnosis of colorectal tumors were estimated with 95% confidence intervals (CIs).

RESULTS

Ninety-two colorectal tumors (64 malignant, 28 benign) were confirmed in 71 patients (prevalence, 71/101; 70%). Overall sensitivity for colorectal tumor detection was 87% (80/92; 95%CI: 78%-93%) on a per lesion basis. For malignant and benign tumor detection, sensitivity was 100% (64/64; 95%CI: 94%-100%) and 57% (16/28; 95%CI: 37%-76%), respectively. For colorectal tumors ≥10 mm, sensitivity was 99% (76/77; 95%CI: 93%-100%). Seventy-nine of the 83 colorectal tumors ≥6 mm were detected, yielding a sensitivity of 95% (79/83; 95%CI: 88%-99%) for this specific size category. On a per patient basis, WE-MDCT had a sensitivity of 100% (71/71; 95%CI: 94%-100%), a specificity of 100% (30/30; 95%CI: 88%-100%), an accuracy of 100% (101/101; 95%CI: 96%-100%), a positive predictive value of 100% (71/71; 95%CI: 94%-100%), and a negative predictive value of 100% (30/30; 95%CI: 86%-100%) for the diagnosis of colorectal tumor.

CONCLUSION

Our results suggest that WE-MDCT is a promising imaging technique for the detection of malignant colorectal tumors. However, our results should be validated by larger and prospective studies.

Для цитирования: Soyer Philippe, Sirol Marc, Dray Xavier, Placé Vinciane, Pautrat Karine, Hamzi Lounis, Boudiaf Mourad. Detection of colorectal tumors with water enema-multidetector row computed tomography.. Abdominal imaging. 2012. DOI: 10.1007/s00261-012-9844-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.