MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apmr.2011.06.007

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2011

Inaccuracy of a physical strain trainer for the monitoring of partial weight bearing.

Pauser Johannes, Jendrissek Andreas, Swoboda Bernd, Gelse Kolja, Carl Hans-Dieter

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the use of a physical strain trainer for the monitoring of partial weight bearing.

DESIGN

Case series with healthy volunteers.

SETTING

Orthopedic clinic.

PARTICIPANTS

Healthy volunteers (N=10) with no history of foot complaints.

INTERVENTIONS: Volunteers were taught to limit weight bearing to 10% body weight (BW) and 50% BW, monitored by a physical strain trainer.

MAIN OUTCOME MEASURES: The parameters peak pressure, maximum force, force-time integral, and pressure-time integral were assessed by dynamic pedobarography when volunteers walked with full BW (condition 1), 50% BW (condition 2), and 10% BW (condition 3).

RESULTS

With 10% BW (condition 3), forces with normative gait (condition 1) were statistically significantly reduced under the hindfoot where the physical strain trainer is placed. All pedobarographic parameters were, however, exceeded when the total foot was measured. A limitation to 10% BW with the physical strain trainer (condition 3) was equal to a bisection of peak pressure and maximum force for the total foot with normative gait (condition 1). Halved BW (condition 2) left a remaining mean 82% of peak pressure and mean 59% of maximum force from full BW (condition 1).

CONCLUSIONS

The concept of controlling partial weight bearing with the hindfoot-addressing device does not represent complete foot loading. Such devices may be preferably applied in cases when the hindfoot in particular must be off-loaded. Other training devices (eg, biofeedback soles) that monitor forces of the total foot have to be used to control partial weight bearing of the lower limb accurately.

Для цитирования: Pauser Johannes, Jendrissek Andreas, Swoboda Bernd, Gelse Kolja, Carl Hans-Dieter. Inaccuracy of a physical strain trainer for the monitoring of partial weight bearing.. Archives of physical medicine and rehabilitation. 2011. DOI: 10.1016/j.apmr.2011.06.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.