MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-009-9568-x

Медицинская библиотека · Abdominal imaging · 2009

CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.

Neri Emanuele, Faggioni Lorenzo, Cerri Francesca, Turini Francesca, Angeli Simone, Cini Lorenzo, Perrone Franco, Paolicchi Fabio, Bartolozzi Carlo

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Our aim is to compare the radiation dose associated with a low-dose CT colonography (CTC) protocol for colorectal cancer screening with that delivered by double-contrast barium enema (DCBE). CTC of twenty asymptomatic individuals (M:F = 10:10) participating to a colorectal cancer screening program and DCBE of fifteen patients (M:F = 6:9) were evaluated. For CTC, absorbed dose was determined by calculating the dose-length product for each CTC examination from measurements on a CT dose phantom equipped with a CT ion chamber. For DCBE, the free-in-air Kerma at the patient's X-ray entry surface and the Kerma-area product during fluoroscopy and fluorography were measured with a Barracuda system, with fluoroscopy times being recorded blinded to the performing operator. Effective dose at CTC was 2.17 ± 0.12 mSv, with good and excellent image quality in 14/20 (70%) and 6/20 cases (30%), respectively. With DCBE, effective patient dose was 4.12 ± 0.17 mSv, 1.9 times greater than CTC (P < 0.0001). Our results show that effective dose from screening CTC is substantially lower than that from DCBE, suggesting that CTC is the radiological imaging technique of the large bowel with the lowest risk of stochastic radiation effects.

Для цитирования: Neri Emanuele, Faggioni Lorenzo, Cerri Francesca, Turini Francesca, Angeli Simone, Cini Lorenzo, Perrone Franco, Paolicchi Fabio, Bartolozzi Carlo. CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.. Abdominal imaging. 2009. DOI: 10.1007/s00261-009-9568-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.