MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/rpd/ncp172

Медицинская библиотека · Radiation protection dosimetry · 2009

Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana.

Gyekye P K, Schandorf C, Boadu M, Yeboah J, Amoako J K

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Organ and effective doses to 90 patients undergoing some selected fluoroscopic examinations at the Korle-Bu Teaching Hospital were estimated using the Monte Carlo-based program (PCXMC version 1.5). Radiation dose was estimated from free-in-air measurements. The mean effective doses were found to be 0.29 +/- 0.07, 0.84 +/- 0.13, 3.15 +/- 0.44, 6.24 +/- 0.70 and 0.38 +/- 0.05 mSv for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. The dose area product was estimated to be 3.55 +/- 0.95, 16.44 +/- 2.60, 50.81 +/- 7.04, 99.69 +/- 10.85 and 9.32 +/- 0.99 Gy cm(2) for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. Optimisation of procedures is required for barium enema and barium meal examinations.

Для цитирования: Gyekye P K, Schandorf C, Boadu M, Yeboah J, Amoako J K. Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana.. Radiation protection dosimetry. 2009. DOI: 10.1093/rpd/ncp172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.