MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11547-007-0187-8

Медицинская библиотека · La Radiologia medica · 2007

Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.

Lo Re G, Galia M, Bartolotta T V, Runza G, Taibbi A, Lagalla R, De Maria M, Midiri M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to evaluate the accuracy of multidetector computed tomography (MDCT) enteroclysis after oral hyperhydration with isotonic solution in detecting bowel wall alterations in patients with Crohn's disease.

MATERIALS AND

METHODS

Twenty-eight patients with a diagnosis of Crohn's disease established by ileocolonoscopy and histology were enrolled in the study; 15 patients with negative ileocolonoscopy served as controls. In all cases, MDCT enteroclysis was performed after oral administration of 2,000 ml of isotonic solution and intravenous administration of N-butylscopolamine. Axial, isotropic multiplanar and volume-rendered reconstructions were used to evaluate bowel wall thickness, ulceration, contrast enhancement, extraparietal involvement and possible complications.

RESULTS

MDCT enteroclysis identified the typical signs of Crohn's disease in 26 patients (92.8%), with sensitivity of 92.8%, specificity of 100%, positive predictive value 100% and negative predictive value 75%.

CONCLUSIONS

MDCT enteroclysis after oral hyperhydration with isotonic solution showed a high level of accuracy in detecting small bowel changes in patients with Crohn's disease. It can be considered a safe and effective alternative to conventional radiography and small-bowel spiral computed tomography enema, especially in patients who refuse nasojejunal intubation.

Для цитирования: Lo Re G, Galia M, Bartolotta T V, Runza G, Taibbi A, Lagalla R, De Maria M, Midiri M. Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.. La Radiologia medica. 2007. DOI: 10.1007/s11547-007-0187-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.