Validation of postural radiographs as a way to measure change in pelvic obliquity.

Fann Alice V

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the validity of using postural radiographs to assess change in pelvic obliquity.

DESIGN

Blinded comparison of reference lines and instrument development of postural radiographs.

SETTING

Veterans Administration hospital.

PARTICIPANTS

Thirty-nine subjects with no history of low back pain.

INTERVENTION: Repeated postural radiographs without heel lifts and with (1/4)-in (6.35-mm) and (1/2)-in (12.7-mm) heel lifts.

MAIN OUTCOME MEASURE: The change of pelvic obliquity as measured by the intersulcate, interalar, and sacral surface lines on postural radiographs.

RESULTS

A (1/4)-in heel lift resulted in changes of 4.6+/-4.0mm, 3.6+/-3.1mm, and 5.8+/-3.9mm and a (1/2)-in heel lift in changes of 7.8+/-4.3mm, 7.8+/-4.6mm, and 5.2+/-3.8mm for the intersulcate, interalar, and sacral surface lines, respectively. Pearson correlation coefficients were used to correlate the change in pelvic obliquity with the corresponding heights of heel lifts; for the (1/4)-in heel lift, they were.67,.88, and.71, and for (1/2)-in heel lift they were.73,.79, and.87 for the intersulcate, interalar, and sacral surface lines, respectively (all P<.001).

CONCLUSION

All the reference lines seem to be valid measures of change of pelvic obliquity relative to the size of the lifts (ie, the changes in pelvic obliquity seem to be causally related and correlated with the lifts). These results also suggest that postural radiographs can be used to determine the magnitude of pelvic obliquity.

Для цитирования: Fann Alice V. Validation of postural radiographs as a way to measure change in pelvic obliquity.. Archives of physical medicine and rehabilitation. 2003. DOI: 10.1053/apmr.2003.50067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.