A neuromuscular test battery for osteoporotic women: a pilot study.

Kerschan-Schindl K, Uher E, Grampp S, Kaider A, Ghanem A H, Fialka-Moser V, Preisinger E

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To examine the efficacy of a short neuromuscular test battery in elderly women suffering from osteoporosis in accordance with the World Health Organization criteria, with and without a history of fractures. Reduced bone mass and a high likelihood of falling increase the risk of osteoporotic fractures. There is a need for neuromuscular tests to identify individuals at risk for falls and fractures.

DESIGN

The women were assessed twice. Forty-two women, with a mean age of 70.0 +/- 5.1 (SD) yr, completed the first assessment. The number of postmenopausal fractures and the women's history with regard to agility and falls were assessed. The women performed neuromuscular tests (one-leg stance, tandem walk, and body sway); bone mineral density of the spine and femoral neck were measured. For the follow-up assessment, 13.2 +/- 1.3 mo later, 39 women were studied. The same outcome measurements were obtained at both evaluations.

RESULTS

During the observation period, five women fell once and one woman fell twice; there were only two vertebral fractures and no nonvertebral fracture. Neuromuscular performance did not change during this observation period. The median changes in bone mineral density between the two assessments were clinically not relevant. A comparison between patients suffering from established osteoporosis and osteoporotic patients without a history of postmenopausal fractures showed that both groups of patients did not differ with respect to age, neuromuscular performance, bone mineral density, and fear of falling.

CONCLUSION

This neuromuscular test battery is a feasible and practical tool because it is brief and economical to perform. However, its efficacy as a predictor of fractures must be tested in additional studies with a long-term follow-up and a larger group of subjects.

Для цитирования: Kerschan-Schindl K, Uher E, Grampp S, Kaider A, Ghanem A H, Fialka-Moser V, Preisinger E. A neuromuscular test battery for osteoporotic women: a pilot study.. American journal of physical medicine & rehabilitation. 2001. DOI: 10.1097/00002060-200105000-00006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.