MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.2223010811

Медицинская библиотека · Radiology · 2002

Crohn disease with endoscopic correlation: single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging.

Low Russell N, Sebrechts Christopher P, Politoske Douglas A, Bennett Michael T, Flores Sergio, Snyder Richard J, Pressman Jeffrey H

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare T2-weighted breath-hold single-shot fast spin-echo (SE) and gadolinium-enhanced spoiled gradient-echo (GRE) MR imaging with contrast material administered orally and rectally for evaluating patients with Crohn disease.

MATERIALS AND

METHODS

Twenty-eight patients with Crohn disease received 2% barium sulfate and water enema. The abdomen and pelvis were imaged with transverse and coronal single-shot fast SE and gadolinium-enhanced spoiled GRE MR imaging. Two radiologists reviewed the two types of images for bowel disease. The extent, severity, and conspicuity of the disease were determined. Proof of bowel disease at MR imaging was compared with that at endoscopy, barium study, and surgery. Statistical analysis was performed with the McNemar test.

RESULTS

Twenty-five of 28 patients had proven abnormal bowel segments. The per-patient sensitivity of gadolinium-enhanced spoiled GRE MR imaging for the two radiologists was 100% and 96% versus 60% and 60% (P <.05) with single-shot fast SE MR imaging. Gadolinium-enhanced spoiled GRE MR images depicted more segments (54 and 52 of 61 segments; sensitivity, 89% and 85%, respectively) of the diseased bowel than did single-shot fast SE MR images (31 and 32 of 61 segments; sensitivity, 51% and 52%, respectively; P <.001). Severity of Crohn disease was correctly depicted at gadolinium-enhanced spoiled GRE imaging in 93% of patients versus in 43% of patients at single-shot fast SE imaging.

CONCLUSION

In patients with Crohn disease, gadolinium-enhanced fat-suppressed spoiled GRE MR imaging better depicted the extent and severity of intestinal disease compared with single-shot fast SE imaging.

Для цитирования: Low Russell N, Sebrechts Christopher P, Politoske Douglas A, Bennett Michael T, Flores Sergio, Snyder Richard J, Pressman Jeffrey H. Crohn disease with endoscopic correlation: single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging.. Radiology. 2002. DOI: 10.1148/radiol.2223010811.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.