Multicenter, Multivendor Development and Validation of Automated Liver Prescription.
Аннотация
BACKGROUND
Manual prescription of liver MRI volumes introduces inter-operator variability and prolongs exam duration. Artificial intelligence (AI)-based prescription has been demonstrated, but existing work has been limited to single-vendor settings.
PURPOSE: To develop and validate an AI model for automated liver MRI prescription using a large, consecutive, multicenter dataset encompassing multiple vendors, field strengths, localizer sequences, and liver pathologies.
STUDY TYPE: Retrospective.
POPULATION: A total of 11,012 patients (5928 female) who underwent liver MRI exams across three vendors (GE HealthCare, Philips Healthcare, Siemens Healthineers) at three institutions, split into training/validation/test sets (70/10/20%). Liver disorders included cirrhosis, ascites, portal hypertension, and iron overload.
FIELD STRENGTH/SEQUENCE: Three-plane localizers acquired using single-shot fast spin echo (68.3%) and gradient echo (31.7%) at 1.5 T (52.8%) and 3 T (47.2%).
ASSESSMENT: A YOLOv8 object detection model was trained to detect the liver, torso, and arms on localizer images. Automated prescription accuracy was assessed using three-dimensional intersection-over-union (IoU3D) for axial, coronal, and sagittal prescriptions. Subgroup analyses evaluated performance across technical and patient-related factors.
STATISTICAL TESTS: Mann-Whitney U tests with Bonferroni correction, Kruskal-Wallis tests, Wilcoxon signed-rank tests, Spearman correlation. Effect sizes were calculated using rank-biserial correlation (rrb) and epsilon-squared (ε2). p < 0.05 was considered statistically significant.
RESULTS
Median axial prescription IoU3D was 0.963 (interquartile range: 0.946-0.976), with median IoU3D above 0.940 for coronal and sagittal prescriptions. For axial prescriptions, margins less than 4 mm in each direction were required to achieve complete coverage of manual prescriptions in 90% of cases in the held-out test set. Effects were negligible to small across vendors, field strengths, localizer sequences, and patient factors (rrb ≤ 0.16, ε2 ≤ 0.01).
DATA
CONCLUSION
A single multivendor model achieved accurate automated liver MRI prescription without clinically meaningful performance differences across vendors, field strengths, localizer sequences, or patient factors.
EVIDENCE LEVEL: 2.
TECHNICAL EFFICACY: Stage 1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.