DOI 10.1016/j.rec.2025.09.007

Медицинская библиотека · Revista espanola de cardiologia (English ed.) · 2025

Failure of the new underexpansion criteria to predict outcomes after ACURATE neo2 valve implantation: results from an independent multicenter registry.

Pan Manuel, González-Manzanares Rafael, Blas Sergio García, Ruiz-Nodar Juan M, Izaga Torralba Elena, Abril Molina Alba, de la Torre-Hernández José M, Tébar Daniel, Gallo Ignacio, Rivadulla Claudio, Torres Saura Francisco, Gómez Menchero Antonio E, Díaz José F, Veiga Fernández Gabriela, Vila-García Joaquín, Herrero Brocal Marta, Moreno Raúl, Sanchis Juan, Ojeda Soledad

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION AND

OBJECTIVES

Suboptimal outcomes with the ACURATE neo2 valve have been attributed to valve frame underexpansion, reported in approximately 20% of cases according to 3 recently proposed angiographic criteria. We aimed to validate these criteria in an independent registry with a 2-year follow-up.

METHODS

This registry included 696 patients with severe aortic stenosis treated with the ACURATE neo2 valve at 7 experienced centers. Underexpansion was defined as the presence of at least 1 of the 3 criteria; the boundary box method was also applied to assess postparallelism. The primary endpoint was a composite of all-cause mortality, stroke, or heart failure hospitalization at 2 years.

RESULTS

The mean age was 81± 5.8 years. Based on the 3-criteria method, underexpansion was identified in 154 patients (22%). There were no significant differences in the primary endpoint between the 2 groups. The cumulative incidence of the composite outcome was 13.7% vs 11.0% at 1 year and 21.0% vs 17.4% at 2 years for the underexpanded and expanded groups, respectively (P=.535). Similarly, no differences were observed with the boundary box method. On multivariable analysis, underexpansion was not independently associated with the primary endpoint (HR, 1.15; 95%CI, 0.73-1.80, P=.537). The only variables significantly associated with major adverse events at 2-years were atrial fibrillation, diabetes mellitus, and reduced glomerular filtration rate.

CONCLUSIONS

The presence of at least 1 angiographic underexpansion criterion after ACURATE neo2 implantation did not predict adverse outcomes at follow-up.

Для цитирования: Pan Manuel, González-Manzanares Rafael, Blas Sergio García, Ruiz-Nodar Juan M, Izaga Torralba Elena, Abril Molina Alba, de la Torre-Hernández José M, Tébar Daniel, Gallo Ignacio, Rivadulla Claudio, Torres Saura Francisco, Gómez Menchero Antonio E, Díaz José F, Veiga Fernández Gabriela, Vila-García Joaquín, Herrero Brocal Marta, Moreno Raúl, Sanchis Juan, Ojeda Soledad. Failure of the new underexpansion criteria to predict outcomes after ACURATE neo2 valve implantation: results from an independent multicenter registry.. Revista espanola de cardiologia (English ed.). 2025. DOI: 10.1016/j.rec.2025.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.